User manual

Receiver
BACK
5.2V
VO LT
3.5V
L-VOLT
3.0 3.0
R
40.0
6.0 6.0
0 0
70
-20
+26°C
TEMP
- 58dB
- 52dB
T
0020ms
L
075%
S
100%
Q
NEXT
This display offers a graph of the data from the display
"RX DATAVIEW“ of the "Telemetry" menu "SETTING &
DATA VIEW, page 116.
The abbreviations have the following meanings:
Value Explanation
Q Quality expressed as the percentage of
transmitter signal packages arriving at the
receiver
S Signal strength expressed as the
percentage of the transmitter signal
arriving at the receiver
R dB Level in dBm expressed as the
percentage of the transmitter signal
arriving at the receiver
T dB Level in dBm expressed as the
percentage of the receiver signal arriving
at the transmitter
L Shows the longest time in ms in which
the data packets are lost during a
transmission from the transmitter to
receiver
VOLT Current operating voltage of the receiver
power supply in Volts
L-VOLT Lowest operating voltage of the receiver
power supply since the last startup in
Volts
TEMP The thermometer visualizes the current
operating temperature of the receiver
Note:
Detailed explanations of the terms in the
"Value" column can be found in the section
"RX DATA VIEW", starting on page 116.
General module
BACK
NEXT
000000rpm
RPM
00000mAh
mAh
100000 15000
QUA 100
40.0 150.0
200000 30000
0 0
80.0
300.0
0 0
00.0V
BATT
000.0A
AMP
0000m
ALT
BACK
NEXT
00.0V 00.0V
1-BAT-2
BAT 1
80.0
m/s -000.2m/s m/3s 000m/3s
70
100
0
0
3.0V
-20
0.0
-20
0
-020°C -020°C
1-TEMP-2
00000ml
FUEL
2525
40.0
40.0
50
0.0
0.0
0.0
0.0
0.0
These two displays visualize the data of a general
engine module (order No. 33610) or a general air
module (order No. 33611) that may be connected to the
receiver.
Further information on these modules can be found in
the Annex or on the Internet at www.graupner.de for the
respective product.
Depending on the configuration of the modules with ad-
ditional sensors, the following data can be permanently
shown on the display.
Firmware versions up to and including V 1.020
The two displays appear alternately about every 4
seconds.
Firmware versions V 1.021 and above
In order to switch between the two displays, touch one
of the dials or scales in the display with a finger or the
provided stylus.
1st Display
At the top edge of the display, "QUA" identifies the
quality, expressed as a percentage, of the signal coming
from the transmitter.
The graphic at the top left shows the speed detected
by a speed sensor connected to the module, and the
graphic adjacent to the right shows the remaining
charge of the connected battery.
Note:
To correctly display the data, the relevant
number of blades and the charge must be
entered beforehand in the "Telemetry" menu.
The graphic at the bottom left shows the current
voltage of the battery connected to the module, and the
adjacent graph to the right shows the momentary flow of
current. The graph at the right edge of the display shows
the current height relative to the location.
2nd Display
The current ascent/descent is displayed at the top edge
in m/1 s and m/3 s.
The two graphics to the left show the current voltage
measured by the temperature and voltage sensors
(order No. 33612 and 33613) connected to the model
from up to two batteries (BAT-1 and BAT-2). They also
show the corresponding temperature: On the left side
you can see the data of sensor 1 and on the right side
the data of sensor 2.
214
Telemetry data display