With the control element (gas/pitch control stick),
a vertical green line is moved synchronously in the
graph between the two endpoints "L" and "H". The
momentary control stick position is also displayed
numerically in the line "IN" (-100 % to +100 %). The
intersection of this line with the curve is identified
as "OUT" and can be varied at the support points
between -125% and +125%. The control signal which
is changed in this way then affects all of the following
mixing and coupling functions.
In the following example, the control stick is exactly
halfway between the middle and end of its path,
at +50% of the control path, and generates an
output signal that is also +50% due to the linear
characteristic.
Between the two endpoints "L" and "H", up to
five additional support points can be set, and the
distance between neighbouring support points may
not be less than approximately 25%.
NORMAL
Starlet
ENT
TRIM
+050%
+050%
000%
?
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
ENT button
Move the control stick. As long as a ? is next to
the "POINT", you can set the next support point by
touching the ENT button. At the same time, a green
point appears at the intersection between the yellow
and green lines:
NORMAL
Starlet
ENT
TRIM
+050%
+050%
000%
?
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
Once the green line is moved with the control stick
around the point, it becomes red, and the "?" is
replaced with a number, and the point to value
appears in the value field to the right of the support
point number:
NORMAL
Starlet
ENT
TRIM
+050%
+050%
+050%
1
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
The sequence in which the up to 5 points between
the end points "L" and "H" are generated does not
matter since the support points are automatically
renumbered sequentially from left to right after one
support point is set or deleted, for example:
NORMAL
Starlet
ENT
TRIM
–050%
–050%
–050%
1
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
Deleting a support point
In order to delete the set support points 1 to 5, move
the vertical green line with the control stick next to
the relevant support point. As long as the support
point number and the associated value appear in the
"POINT" line and the point is red (see figure below),
you can delete it by touching the ENT button, for
example:
NORMAL
Starlet
ENT
TRIM
000%
000%
000%
2
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
Touch
NORMAL
Starlet
ENT
TRIM
000%
000%
000%
?
BACK
IN
OUT
POINT
OFF
INC
DEC
Y-axis
X-axis
ST ON
CURVE
S
Pitch min.
FORWARD
Changing the support point value
X-axis button (X-axis)
Activate this function by touching the button at
the bottom edge of the display with a finger or the
provided stylus.
You can then move an active (red) point to the right
with the INC button, and to the left with the DEC
button, for example:
176
Helicopter model function menu - PIT.CRV
S1006_mz-24.3.en.indd 176 17.12.2014 15:22:37