User manual
BACK
NORMAL
CH
CH6
CH7
CH8
CH5-12
+100%
+100%
INC
RES
DEC
+100%
CH5
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
+100%
CH10
CH11
CH12
CH9
D/R –
D/R –
D/R + D/R +
Starlet
S
NORMAL
CH
CH6
CH7
CH8
CH5-12 CTL
000%
000%
INC
RES
DEC
000%
CH5
000%
000%
000%
000%
000%
CH10
CH11
CH12
CH9
OFFSET OFFSET
BACK
Starlet
S
Note:
In contrast to the displays of the 12-channel
mz-24 HoTT transmitter shown in this
section, only channels 1 … 9 are shown in the
display of the 9-channel mz-18 HoTT transmitter.
Q.Link-dependent D/R and EXP settings
If you have created Quick Links in the submenu
"Q.Link", page 168, and have assigned an appropriate
name, it appears at the top right in green font such
as "NORMAL". Activate the corresponding switches if
desired to switch between Quick Links.
Setting symmetrical or asymmetrical values
By default, the dual rate and/or expo values for the
selected control function are set for each control side.
After switching the option "SYM", added to the bottom
line as of firmware version 1020, from OFF to ON , a
simultaneous (symmetrical) setting of both control sides
is possible.
D/R function
If you want to switch between two versions, assign a
control in the line "CTL" as described in the section
"Control, switch and control switch assignment" on
page 38.
BACK
CH
D/R
EXP
CTL
RUDD
+100%
+100%
NULL
INC
RES
DEC
NORMAL
000%
000%
Starlet
S
SYM
OFF
Select
CLR
NO
If desired, a control switch as well, for example:
BACK
CH
D/R
EXP
CTL
RUDD
+100%
+100%
ST 4
INC
RES
DEC
NORMAL
000%
000%
Starlet
S
SYM
OFF
Select
With a finger or the provided stylus, touch the left value
field in the "D/R" line to set a dual rate value to the
minus side of the control travel, and/or on the right to set
a dual rate value on the plus side of the control travel,
for example:
BACK
CH
D/R
EXP
CTL
RUDD
+100%
+100%
ST 4
INC
RES
DEC
NORMAL
000%
000%
Starlet
S
SYM
OFF
Select
Touch
The color of the field switches from red to blue:
BACK
CH
D/R
EXP
CTL
RUDD
+100%
+100%
ST 4
INC
RES
DEC
NORMAL
000%
000%
Starlet
S
SYM
OFF
Select
Set the desired value with the INC or DEC button at
the right edge.
The adjustment range is ±125%.
Use the same procedure for a value on the plus side of
the control travel, for example:
BACK
CH
D/R
EXP
CTL
RUDD
+050%
+125%
ST 4
INC
RES
DEC
NORMAL
000%
000%
Starlet
S
SYM
OFF
Select
The dual rate curve is simultaneously displayed in the
graph.
Touch the RES button to reset a changed value in the
blue (and hence active) field to the default.
NOTE:
For safety reasons, the dual rate value should
not fall below 20%.
172
Helicopter model function menu - D/R,Expo
S1006_mz-24.3.en.indd 172 17.12.2014 15:22:35