User manual
Value Explanation
Possible
settings
CH
OUTPUT
TYPE
Channel sequence
or type of aggregate
symbol
ONCE, SAME,
SUMI, SUMO
and SUMD
ALL-MAX (servo travel on the "+" side)
In this line, set the maximum servo travel on the plus
side of the control travel for the servo test.
2000 µs corresponds to a full deflection on the "+" side
of the servo travel, and 1500 µs corresponds to the
neutral position.
Make sure that the servos do not strike anything during
the test routine.
ALL-MIN (servo travel on the "–" side)
In this line, set the maximum servo travel on the minus
side of the control travel for the servo test.
1000 µs corresponds to a full deflection on the "–" side
of the servo travel, and 1500 µs corresponds to the
neutral position.
Make sure that the servos do not strike anything during
the test routine.
TEST (start/stop)
In this line, briefly touch the SET button at the bottom
right of the display with a finger or the provided stylus to
start and stop the servo test integrated in the receiver.
Graubele
VARIO
GPS
ENT
SET
ESC
RX SERVO TEST <
ALL-MIN : 1200µsec
>TEST : STOP
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALL-MAX : 2000µsec
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Use the INC or DEC button to select "START" …
Graubele
VARIO
GPS
ENT
SET
ESC
RX SERVO TEST <
ALL-MIN : 1200µsec
>TEST : START
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALL-MAX : 2000µsec
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
BACK
RECV
GENE
ELEC
DEC
INC
ESC
… and touch the SET button again at the bottom right
of the display to start the test. The entry field returns to
normal:
Graubele
VARIO
GPS
ENT
SET
ESC
RX SERVO TEST <
ALL-MIN : 1200µsec
>TEST : START
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALL-MAX : 2000µsec
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
BACK
RECV
GENE
ELEC
DEC
INC
ESC
To stop the servo test, reactivate the entry field as
described above, select "STOP", and confirm by
touching the SET button at the bottom right.
ALARM VOLT (receiver low voltage warning)
The receiver voltage is monitored with "ALARM VOLT".
It can be set between 3.0 and 7.5 V. When the voltage
falls below the set alarm threshold, a warning tone
sounds, and "VOLT.E" appears in red at the top right in
all "RX…" displays.
Graubele
VARIO
GPS
ENT
SET
ESC
RX SERVO TESTVOLT.E
ALL-MIN : 1200µsec
TEST : START
>ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
ALL-MAX : 2000µsec
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
BACK
RECV
GENE
ELEC
DEC
INC
ESC
In the "RX DATAVIEW" display, the parameter "R-VOLT"
is displayed in red.
Graubele
VARIO
GPS
ENT
SET
ESC
RX DATAVIEW VOLT.E
S–STR100% R–TEM.+28°C
L PACK TIME 00010msec
R-VOLT :03.7V
L.R-VOLT:04.5V
S–QUA100%S–dBM–030dBM
SENSOR1 :00.0V 00°C
SENSOR2 :00.0V 00°C
BACK
RECV
GENE
ELEC
DEC
INC
ESC
ALARM TEMP +/- (receiver temperature monitoring)
These two options monitor the receiver temperature. You
can program a bottom threshold "ALARM TEMP-"
(-20 … +10°C) and an upper threshold "ALARM
TEMP+" (+50 … +80°C). If the upper lower thresholds
are exceeded, a continuous warning tone sounds, and
"TEMP.E" appears in red at the top right in all receiver
displays. On the display page "RX DATAVIEW", the
parameter "R-TEM" is also displayed in red.
Make sure that the temperature of your receiver
remains within the permissible range under all operating
conditions (ideally between -10 and +55°C).
124
Function menu - Telemetry | SETTING & DATA VIEW