User manual

manner.
C: EXP = +100 % and D/R = 70%
The servo reacts weakly to control stick movement
around the neutral position. The curve becomes
steeper as the rudder deflection increases.
Note:
The control characteristics that are
programmed here affect the mapped receiver
outputs.
5CH FUNCTION: "SERVO" or "SENSOR"
Graubele
VARIO
GPS
ENT
SET
ESC
RX CURVE <>
TYPE : B
CURVE2 CH : 03
TYPE : B
CURVE3 CH : 04
>CURVE1 CH : 02
TYPE : B
5CH FUNCTION:SERVO
BACK
RECV
GENE
ELEC
DEC
INC
ESC
With certain receivers, a certain servo connector is
designed to be switchable instead of an independent
telemetry connector. For example, with the GR-12L
receiver that comes standard with mz-18 HoTT and
mz-24 HoTT sets, a telemetry sensor can also be
connected to servo connector 5 identified with an
additional "T" …
Servo
Sensor
OR
L
No.S1012
… as well as the adapter cable (order No. 7168.6S) for
updating the receiver.
In order for the connected device to be correctly
identified by the receiver, servo connector 5 needs to be
switched from "SERVO" to "SENSOR" and vice versa.
Use the INC button to move the ">" icon at the left
edge in front of the last line, and touch the SET button
at the bottom right of the display:
Graubele
VARIO
GPS
ENT
SET
ESC
RX CURVE <>
TYPE : B
CURVE2 CH : 03
TYPE : B
CURVE3 CH : 04
CURVE1 CH : 02
TYPE : B
>5CH FUNCTION:SERVO
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Use the INC or DEC button to select the alternative
setting "SENSOR":
Graubele
VARIO
GPS
ENT
SET
ESC
RX CURVE <>
TYPE : B
CURVE2 CH : 03
TYPE : B
CURVE3 CH : 04
CURVE1 CH : 02
TYPE : B
>5CH FUNCTION:SENSOR
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Touch the SET button again at the bottom right of the
display to finalize your selection and, if desired, return
to the main display of the transmitter by repeatedly
pressing the BACK button at the top left of the display.
RX SERVO TEST
With the RX SERVO TEST function, you can test the
servos connected to the currently active receiver:
Graubele
VARIO
GPS
ENT
SET
ESC
RX SERVO TEST <
ALL-MIN : 1200µsec
TEST : STOP
ALARM VOLT : 3:8V
ALARM TEMP+: 55°C
>ALL-MAX : 2000µsec
ALARM TEMP–:–10°C
CH OUT TYPE:ONCE
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Value Explanation
Possible
settings
ALL-MAX Servo travel on the
"+" side for all servo
outputs for the servo
test
1500 … 2000 µs
ALL-MIN Servo travel on the
"–" side for all servo
outputs for the servo
test
1500 … 1000 µs
TEST Test procedure START / STOP
ALARM
VOLT
Alarm threshold for
the receiver’s low
voltage warning
3.0 … 7.5 V
Factory setting:
3.8 V
ALARM
TEMP+
Alarm threshold
when the receiver
temperature is too
high
50 … 80 °C
Factory setting:
55°C
ALARM
TEMP–
Alarm threshold
when the receiver
temperature is too
low
-20 … +10 °C
Factory setting:
-10°C
123
Function menu - Telemetry | SETTING & DATA VIEW
S1006_mz-24.3.en.indd 123 17.12.2014 15:22:05