User manual
FAIL SAFE ALL (global fail safe setting)
This submenu allows you to easily determine the fail
safe positions of servos by pressing a button similar to
the "Fail Safe" submenu, described on page 84:
Touch the SET button at the bottom right of the display
with a finger or the provided stylus to switch to the
"FAIL SAFE ALL" line and activate the value field. "NO"
is displayed in red: Set the parameter with the INC
or DEC button to "SAVE".
Use the transmitter's control elements to simultaneously
move all servos that you have to assigned (or wish
to assign) "FAI(L) SAFE" in the "MODE" line into the
desired fail safe position, and hold it.
In the bottom "POSITION" line, the current servo
position is displayed for the selected OUTPUT CH, for
example:
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
INPUT CH: 01
MODE : FAI SAFE
F.S.POS : 1150µsec
DELAY : 0:25sec
OUTPUT CH: 01
>FAIL SAFE ALL: SAVE
POSITION : 1234µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Touch the SET button at the bottom right of the display
to switch the display from "SAVE" to "NO".
This saves the positions of all of the servos affected by
these measures and simultaneously transfers them to
the "F.S.Pos." line so that the receiver can access them
in a malfunction.
You can now release the control elements of the
transmitter.
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
INPUT CH: 01
MODE : FAI SAFE
F.S.POS : 1234µsec
DELAY : 0:25sec
OUTPUT CH: 01
>FAIL SAFE ALL: NO
POSITION : 1234µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Switch off the transmitter and check the fail safe
positions by checking the servo travel.
Fail Safe in combination with channel mapping
To make sure that mapped servos react in the same
way even in a malfunction, that is, servos that are
controlled by common control channel (INPUT CH), the
corresponding settings of the INPUT CH determine the
behaviour of mapped servos.
If for example servo connectors 6, 7 and 8 of a receiver
are mapped by assigning the same control channel "04"
as the INPUT CH to OUTPUT CH (servo connectors)
06, 07 and 08 …
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
>INPUT CH: 04
MODE : HOLD
F.S.POS : 1500µsec
DELAY : 0:25sec
OUTPUT CH: 06
FAIL SAFE ALL: NO
POSITION : 1234µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
>INPUT CH: 04
MODE : HOLD
F.S.POS : 1500µsec
DELAY : 0:25sec
OUTPUT CH: 07
FAIL SAFE ALL: NO
POSITION : 1345µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
>INPUT CH: 04
MODE : HOLD
F.S.POS : 1500µsec
DELAY : 0:25sec
OUTPUT CH: 08
FAIL SAFE ALL: NO
POSITION : 1456µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
… then INPUT CH 04 determines the fail safe behaviour
of these three servos connected to control channel
4 fully independent of the settings of the respective
OUTPUT CH:
Graubele
VARIO
GPS
ENT
SET
ESC
RX FAIL SAFE <>
INPUT CH: 04
>MODE : FAI SAFE
F.S.POS : 1500µsec
DELAY : 0:25sec
OUTPUT CH: 04
FAIL SAFE ALL: NO
POSITION : 1500µsec
BACK
RECV
GENE
ELEC
DEC
INC
ESC
This is also true when INPUT CH 01 is used for
mapping:
120
Function menu - Telemetry | SETTING & DATA VIEW
S1006_mz-24.3.en.indd 120 17.12.2014 15:22:04