In normal model operation, the corresponding servo contrast-
ingly acts according to the set "MODE" in a malfunction.
DELAY (fail safe reaction time or delay)
This line specifies how long the receiver is going to keep the RC com-
ponents connected to it, after the connection has been terminated,
at their most recently received positions before forwarding the pre-
viously stored fail-safe positions to the connected components. This
setting is adopted by all the channels and only affects the servos pro-
grammed for "FAI(L) SAFE" mode.
The setting is carried out in steps of 0.25 s as described below under
"Programming step-by-step" under OUTPUT CH.
Factory setting: 0.75 s.
FAIL SAFE ALL (global fail safe setting)
This submenu allows you to set the fail-safe positions of RC compo-
nents with a "pushbutton" in a similarly simple way as the "Fail Safe"
menu of the transmitter mz-12 Pro HoTT:
Programming step-by-step
1. Move to the line "FAIL SAFE ALL" by using the selection keys.
2. Push the ENT key to activate the value field.
"NO" is displayed inverted:.
3. Use the upper or lower selection buttons to change the value field
to "SAVE".
ശ Use the transmitter control elements to AT THE SAME TIME
move all the RC components, those that you have assigned in
the "MODE" "FAIL SAFE" line and/or the others which have to
take a specific position during the switch-on phase of the
receiver system, to the desired fail-safe position and keep
them still.
ശ In the bottom "POSITION" line, the current servo position is
displayed for the selected OUTPUT CH.
4. Push the ENT key.
ശ The display in the value field changes again from "SAVE" to
"NO".
ശ This saves the positions of all of the RC components affected
by these measures and simultaneously transfers them to the
"F.S.Pos." line so that the receiver can access them in a mal-
function.
5. You can now release the control elements of the transmitter.
6. Carefully switch off the transmitter and check the fail-safe posi-
tions on the basis of the servo positions.
7. Eventually repeat the process.
RX FAIL SAFE V6.37
INPUT CH: 01
MODE : FAI-SAFE
F.S.POS. : 1500µsec
DELAY : 0.75sec
OUTPUT CH: 01
POSITION : 1670µsec
FAIL SAFE ALL: SAVE