Operation Manual

English
English
INNOVATION & TECHNOLOGIE
50 51
The battery temperature is higher than the set maximum tem-
perature.
The charger is overheated! Wait until it cools again! If the
error message is displayed permanently, please contact the
service.
No balancer connected.
The balancer has stated (cell number in parentheses) too high
cell voltage.
The balancer has stated (cell number in parentheses) too low
cell voltage.
The current of the connected motor is too high. Please check
your parameters.
The motor was stopped because the other output is in use.
Please check your parameters.
Errors in calibration or in the circuits of the device. If the error
message appears repeatedly, please contact the service.
The cell count in the menu charge / discharge and Sync Mode
menu does not match with the detected number of cells on
Channel 1 and Channel 2.
Troubleshooting
Problem Possible causes
When connecting the
charger the display
remains dark
Check that the external power supply meets the requirements of the
charger and that all cables are properly connected. If the problem per-
sists, contact the Service.
The charger does not
recognize the battery
Check whether the battery is properly connected to the charge port
and the balancer.
Check whether a cell of the battery is defective.
The battery voltage is
too low after charge
Check whether the charge settings are correct.
Check the set delta peak value of NiCd / NiMH batteries.
Check the connecting cable of the battery.
Discharge mode is not
retrieved
Check if the selected cell voltage matches the battery features.
Check whether a cell of the battery is defective.
Battery is not fully
charged after the maxi-
mum charging time
Charge the battery pack. Run a full cycle charge process by improving
the capacity (battery has been stored for too long or is consumed).
Check whether in the charge cycle, the minimum discharge voltage
correctly is set.