Operation Manual
English
English
INNOVATION & TECHNOLOGIE
38 39
Turn afterwards continuously by hand the shaft of the motor for about 5 sec-
onds. Once the sensor is detected and is ne too, appears OK on the left of
the screen instead of the four points. Now you can check the functionality of
your controller / motor combination as needed using the servo test function.
In order to check the motor speed and power, as shown in the gure below,
you need the optional splitter, Order Nr. S8002 grind between motor, controller
and charger.
Submenu “MOTOR“
In this sub-menu “MOTOR” you can choose by simply tapping the correspond-
ing icons as break-in program, a motor test program with max. four possible
combinations of voltage and duration as well as a motor test program, in all
three parts of the program the charger acquires both the power supply as well
as the power control of the connected brushed motor.
Display “Break-in“
Connect your brushed motor directly to output CH1 or CH2 and select the appropriate channel
from the display.
After opening the submenu “BREAK-IN” pull down in the lines “time” and “voltage” you may deem
suitable values. Pressing the ENTER button under the display it starts the break-in process of your
brushed motor and the starting of the motor is soft.
1 After tap the minutes and / or seconds eld to select the period of break-in
process (Setting range: 0 m / s 0 ... 300 m / 59 s, default is 5 m / s 0)
2 After tap the voltage eld line to select the operating voltage value supplied
by the battery charger for the break-in process (setting range: 0.1 V ... 24 V
in 0.1 V increments, default value: 7.2 V)
3 Displays the period since the start of the break-in operation
4 Displays the actual output voltage or charge voltage of the buffer capacitor
Pressing the STOP button at the bottom of the display stops the operation.
Display “Program“
Connect your brushed motor directly to output CH1 or CH2 and select the appropriate channel
from the display.
After opening the submenu “BREAK-IN“ pull down in the lines ”time“ and “voltage“ you may deem
suitable values.
Parameter Short description
Cycle 1 ... 10 cycles adjustable (default 5)
1st … 4th rst to fourth sub-cycle
Volt 0.1 ... 12 V output voltage adjustable in 0.1 V increments
On from 1 ... 37 seconds motor run time
Off from 0 ... 37 seconds pause
Pressing the ENTER button under the display starts the intake of such pre-pro-
grammed cycle of your brushed motor, the motor start-up is always soft.
Pressing the STOP button at the bottom of the display stops the operation.
Display “Motor test“
In this screen is shown the average current and peak current consumption of
the checked brushed motor directly connected to the CH1 or CH2 outputs.
Parameter Short description
Voltage 4.8 or 7.2 volts selectable (default 7.2 V)
1st … 6th rst to sixth sub-cycle
0.0Aa medium current consumption in each sub-cycle (amps
average)
0.0Ap maximum current consumption in each sub-cycle (amps
peak)
It will go through 6 passages, wherein the voltage gradually increases from
passage to passage to maximum supply voltage - up to the value preselected
in the “voltage” line.
The duration of each sub-cycle is 5 seconds and the waiting time between the
sub-cycles is 3 seconds.
Pressing the ENTER button under the display starts the test of your brushed motor, the motor
start-up is always soft.
Pressing the STOP button at the bottom of the display stops the operation.