Operation Manual

English
English
INNOVATION & TECHNOLOGIE
36 37
After the activation of the cycle number by tapping with a nger or with the pen
laced in the side of the charger…
... It is possible to scroll through the data of other cycles with the INC or DEC
key.
Tapping again the cycle number deactivated the selection eld.
Pressing again the DEC button (down arrow) at the bottom of the display brings from the second
screen of the “DATA“ menu to the third:
In this third display of “DATA“ menu are shown graphically the charge/dischar-
ge data.
1 Graphical representation
2 Vc = Voltage center (the center line voltage value actually assigned)
3 Vr = Voltage range (vertical range of the voltage display)
4 After tapping between “AUTO“ and “MANUAL“ switchable. In “manual“
mode are “3“ and “4“ also manually settable.
5 After tapping selectable axis value:
GR(aphic)=V(olt), A(mpere) T(emperature)
6 Factor of the horizontal time axis (AT (automatic) / 1 … 43)
Menu TOOLS
In this menu “Tools“ you can enter by pressing the respective icons in a Servo Test, Engine Test,
ESC Brushless Control + T and a Tire Warmer menu:
To prevent sparking when connecting the terminals of CH1 and CH2 are covered with one
capacitor, that is why the charging voltage in the line “output“ is displayed as long as no
motor is connected.
Submenu Short description
SERVO Test menu for servos and brushless motors with integrated
sensor connection
MOTOR Setup menu for brushed motors
HEATING Warming menu for tires and batteries
E.S.C. Menu for electronic speed controllers with integrated
telemetry connection cable type “Brushless Control + T”
Submenu “SERVO“
Display description
1 Graphic display of the servo position
2 Servo position on the minus side in μs (range 700 ... 1500 μs in increments
of 10 μs)
3 Servo center position in μs (range 700 ... 2300 μs in increments of 1 μs)
4 Servo position on the plus side in μs (setting range: 1500 ... 2300 μs in
increments of 10 μs)
5 Sensor Check
6 Output signal resulting from most recently selected servo position (2, 3 or
4)
7 Operating time
8 Motor speed determined by the speed control
9 Output voltage / charging voltage of the buffer capacitor
10 Kilovolt-display
The “servo test” function of this submenu automati-
cally moves the servo connected to the side “SERVO
TEST” connector as if, for example, the switch of a
transmitter moved continuously and permanently with-
in the set time between its two end points.
Please check carefully the correct polarity of
the servo plug when plugging in the servos,
see gure by side!!!
If you wish to use the additional option to test Brush-
less motors with integrated sensors, connect the
control cable of the controller with the correct polarity
to the “SERVO TEST” connector. The motor sensor cable has to be connected in parallel with the
controller sensor cable to the “SENSOR MOTOR” connector of the charger: