Operation Manual

English
English
INNOVATION & TECHNOLOGIE
28 29
If it is touched the STOP button at the bottom of the display during the actual
discharge process, it appears the display on the left. Tapping “Yes“ will cancel
the further running in the background discharge. Tapping “No“, the window
hides again, and takes the discharge operation run unaffectedly.
After proper completion of the discharge process the charger emits audible
signals and the display shows corresponding informations.
So tap the window and afterwards, if necessary, the STOP or ESC key to re-
verse to basic display.
Menu CYCLE
In the menu „PROFILE“ you have stored the data of your batteries and these can be added to
the menu „CHARGE“ and „DISCHARGE“ to the charge or discharge parameters. In this menu,
you can now create charge / discharge cycles based on these parameters, in which both types of
cycle, as well as the number of cycles and the pause between cycles within the specied limits are
customized.
The parameters offered by this mode depend on the battery type selected in the menu „PROFILE“.
The selected location is displayed in the upper display and, once this eld is highlighted in blue by
touching with a nger or the supplied stylus, it can be selected individually. Similarly proceed with
the other option elds as shown below.
Adjustable Parameters
Parameter Short description
Sequence
Charge Discharge, Discharge Charge
1x Discharge, then Charge Discharge
Number of cy-
cles
1 … 10
C D delay
interval between “Charge” and “Discharge”: 1...30 minutes
D C delay
interval between “Discharge” and “Charge”. 1...30 minutes
D Auto Acquired charge current from menu “CHARGE”. The
charge current can therefore be adjusted only in the menu
“CHARGE”.
C Auto Discharge current acquired from the menu “DISCHARGE”.
The discharge can therefore be adjusted as necessary
only in the menu “DISCHARGE”.
Once the settings are matching with your wishes, go to ...
Start of cycle
… Tap the ENTER button on the bottom right of the display brings on the sec-
ond display page of the „CYCLE“ menu.
In parallel, the battery charger balancer checks the active channel CH1 or CH2
charge and compares the number of cells of the connected battery with the
default settings, then, if necessary, appropriate messages are shown on the
display.
Then you have about ve seconds to change the material transferred from the
menus “CHARGE” or “DISCHARGE” and charge and discharge mode and, if
necessary, set a start delay.
Available combinations of charge and discharge modes
Battery type Charge mode Battery type Discharge mode
NiCd and NiMH batteries AUTO NiCd and NiMH batteries AUTO
NORMAL NORMAL
LINEAR LINEAR
LiFe, LiIo, LiPo batteries CC/CV LiFe, LiIo, LiPo batteries NORMAL
CV-LINK LINEAR
Pb batteries CC/CV Pb batteries NORMAL
LINEAR