Input of an individual battery name
Tap the top box while continuously until an input keyboard for entering a battery name appears.
Field Description
„BATTERY NAME“ eld of the battery name
abc / 123 / ABC switch between the character tables
Spc (Space) Tap this button to insert a space
Del (Delete) Touching this key deletes the rearmost characters
Clr (Clear) Tap this button to delete the current battery name
For data input screen, turn back by pressing the left down ESC button.
The parameters in the input elds “battery type, cell number“ “battery capacity“
change when activated by tapping the desired parameter eld with the INC /
DEC buttons placed at the bottom of the display.
Within a memory eld your settings will be taken from the “upper“ setting in the
“lower“ data area after tapping the lower space eld and alternatively when leaving the menu by
pressing the bottom left ESC button.
To copy your settings to a different location, you also tap the lower space eld of the data area and
then choose now highlighted in blue box with the INC / DEC buttons to select the target. Tapping
the CPY button copies the current parameters of the “upper“ adjustment range in the selected
location.
WARNING
Make absolutely sure that the correct parameters are entered! Incorrect eld valu-
es can not only seriously damage charger and / or battery packs but also result in
re!
Press the ESC button on the bottom left to exit the menu.
Menu CHARGE
Add now the menu “PROFILE” key data concerning your batteries in this menu
“CHARGE” with the corresponding charging parameters. To do this, choose
the battery type and cell number matching the battery to charge. So If neces-
sary, tap with your nger or the pen supplied in a lateral recess of the device
to the “memory eld”. In the blue area now select via the INC / DEC buttons at
the bottom of the display the desired memory location 0 ... 19.
Tap again the eld to deactivate the choice.
Within the set for the selected location in the menu “PROFILE” now they
can be adjusted specications regarding battery type and cell count, the
charge current as well as other parameters as described below in this menu
“CHARGE”.
Adjustable Parameters
• NiCd, NiMH batteries
Parameter Short description
Current The default value, inherited from the “Proles” menu to 1C, can be adapt-
ed within the “Maximum capacity” of the charge port rate and the charger
features, see display 2 of the menu “Settings” on page 43, in the range of
0.1 to a maximum of 30 A.
Delta Peak Sensitivity adjustment of the delta Peak in mV per cell. Default: 5 mV /
cell NiMH (Setting range: 0 ... 15 mV) and NiCd 7 mV / cell (range: 5 ...
25 mV)
Trickle charge OFF, 50 to 500 mA in 50 mA steps, AUTO (default value: OFF)
Maximal tempera-
ture
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
peratures is exceeded.
Maximal capacity Setting range: 10 ... 150% in 5% increments, OFF (default value:
120%). To avoid damage from overcharging, the charge stops when the
limit is exceeded.
Safety timer Setting range: 10 ... 900 minutes in 5 minute increments OFF (de-
fault value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.
• LiFe, LiIo and LiPo batteries
Parameter Short description
Voltage Maximum cell voltage at constant charge (CV)
Current The default value, inherited from the „Proles“ menu to 1C, can be ad-
apted within the „Maximum capacity“ of the charge port rate and the
charger features, see display 2 of the menu „Settings“ on page 43, in the
range of 0.1 to a maximum of 30 A.
Maximal tempera-
ture
Setting range: 10 ... 80 ° C (Default: 50 ° C). If the temperature sensor is
connected, the charge process is stopped automatically when that tem-
peratures is exceeded.
Maximal capacity Setting range: 10 ... 150% in 5% increments, OFF (default value:
120%). To avoid damage from overcharging, the charge stops when the
limit is exceeded.
Safety timer Setting range: 10 ... 900 minutes in 5 minute increments OFF (de-
fault value:
120 min). To avoid damage from overcharging, the charge stops when
the limit is exceeded.