Declaration of conformity

HongAn TECHNOLOGY CO., LTD. Report No.: HA110227-CE
CE Test Report Page 14 of 22
3.3 Test Result
Test Date
27 - JUN - 2011 Tested By
M.S.SHI
Temp.
25
°C
Pressure In Bar
1006 mB
Humidity
50 % Test Condition Mains
DC3V
Description
N/A
Basic StandardEN 61000-4-2
Test Level.
Customer
Apply to
Contact Discharge
Customer
Apply to
Air Discharge
Level Test Voltage (KV) Level Test Voltage (KV)
1 ± 2 1 ± 2
2 ± 4 2 ± 4
3 ± 6 3 ± 8
4 ± 8 4 ± 15
Test Data.
By Product Standard : EN 61326-1, Performance Criteria A B C D
Direct Discharge.
Test Point on EUT Polarity
Test Voltage
(KV)
Performance Criteria
(observed)
Result
Contact Air Contact Air Contact Air
Surface of case
2, 4 2, 4 B B P P
2, 4 2, 4 B B P P
Junction of case
2, 4 2, 4 B B P P
2, 4 2, 4 B B P P
ALL I / O Port& Bracket
2, 4 2, 4 B B P P
2, 4 2, 4 B B P P
Indirect Discharge.
Test Point on EUT Polarity
Test Voltage
(KV)
Performance Criteria
(observed)
Result
VCP HCP VCP HCP VCP HCP
Front
±
2, 4 2, 4 B B P P
Rear
±
2, 4 2, 4 B B P P
Left
±
2, 4 2, 4 B B P P
Right
±
2, 4 2, 4 B B P P
Bottom
±
2, 4 2, 4 B B P P
Performance Criteria (observed)
[A] means “ No loss of function
[B] means “ Self-restoring ”
[C] means “ Reset by operator ”
[D] means “ Damage ”
Result
[P] means “ Pass ”
[F] means “ Fail ”
[N/A] means “Not Tested”
Test Result
Compliance
Noncompliance