Declaration of conformity

HongAn TECHNOLOGY CO., LTD. Report No.: HA110227-CE
CE Test Report Page 13 of 22
3 Electrostatic Discharge Immunity Test
3.1 Test Instrument
Refer to Sec. 1.2 Test Instruments.
3.2 Test Configuration and Procedure
Table-top Equipment
z The EUT was located on a 0.8 m high wooden table standing on the ground reference
plane with a 1.6 * 0.8 m horizontal coupling plane on the top. The EUT and cables was
isolated from the coupling plane by an insulating support 0.5 mm thick.
z In Contact Discharge, the EUT was exposed to minimum 200 discharges, 10 each at
negative and positive polarity on the selected test points ( the selected test points were
marked with red labels on the EUT )
z In Air Discharge, the EUT exposed to minimum of 10 single discharges on the selected
test points.
z The result was observed and analyzed.