Declaration of conformity
HongAn TECHNOLOGY CO., LTD. Report No.: HA110227-CE
CE Test Report Page 10 of 22
2 Radiated Emission Test
2.1 Test Instruments
Refer to Sec. 1.2 Test Instruments.
2.2 Test Arrangement and Procedure
EUT
Pre-Amplifier
Turn Table
10 m
1~ 4 m
Test Receiver
80 cm
Table-top Equipment
z The EUT was place on a non-conductive turntable which was 80 cm above the
horizontal ground plane. The EUT was set 10 m away from the receiving antenna that
was mounted on a non-conductive mast.
z Main cables draped to the ground plane and were routed to the mains power outlet.
The mains power outlet was bonded to and did not protrude above the ground plane.
z The antenna was adjusted between 1 m and 4 m in height above the ground plane and
the Antenna-to-EUT azimuth was also varied during the measurements to find the top
6 maximum meter readings within the frequency range limit as indicated in Sec 2.3.
z The radiated emissions were measured when the Antenna-to-EUT polarization was set
horizontally and vertically.
z The values were recorded.