User's Manual

42 / 48
S1008_X-8E_jh_V1
GR-8 Receiver Telemetry Menu
Display screen (display only)
S-QUA: transmission quality
S-STR: transmission power
S-dBm: transmission power in dBm
RX-TEMP: receiver temperature
LOSS PACK: lost data packets in milliseconds
BATT VOLT: receiver voltage
LOW VOLT: warning threshold for minimum receiver voltage
Warning Thresholds and Telemetry Language Setting Screen
AL RX-V: receiver voltage warning threshold
AL RX-T: receiver temperature warning threshold
AL EX-V: ext. voltage sensor warning threshold
AL EX-T: ext. temperature sensor warning threshold
LANGUAGE: language setting (telemetry menu only)
The current value is shown in brackets
Channel Properties Setting Screen (refer to RF SET section)
Settings:
USR1m50 - ULTRA SIGNAL 1.5msec
FSR3m00 - FAST SIGNAL 3.0msec
SUMD-V2 - FAST SIGNAL BUS 3.0msec
NSR6m00 - NORMAL SIGNAL 6.0msec
NSR12m0 - NORMAL SIGNAL 12.0msec
NSR24m0 - NORMAL SIGNAL 24.0msec
Connected Components Display (display only)
(Refer to Telemetry Menu section)
Fail Safe Setting Screen
F/S MEMORY: To save the data in the receiver, select "YES.
Press ENTER to confirm.
F/S DELAY: Fail Safe delay time
CH1(STR): FREE, HOLD, POSITION
CH2(TH): FREE, HOLD, POSITION
CH3(AUX): FREE, HOLD, POSITION
CH4(AUX): FREE, HOLD, POSITION
(Refer to Fail Safe section)