User's Manual

37 / 48
S1008_X-8E_jh_V1
BACK
NORMAL
SERVO
MST
CH3
SLV
>>
ST
TH
ST
CH3
CH4
CLR
Img.1
Img.2
P/MIX
Mixer setup menu. Assign linear mixers to line numbers 1 and
2; curves mixers to line numbers 3 through 5. Activate mixers
by pressing the first button in the number line to change from
INH (inhibit/off) to ON.
Pressing the buttons in the MST or SLV columns will open a
new display screen. To assign the origin (MST/master) and the
target (SLV/slave), highlight the appropriate button above the
blue line and select the applicable channel button below. To
clear the selection press the CLR button.
Return to the P/MIX menu screen by pressing the BACK button.
An arrow >> button will appear in the SET column.
Press the arrow >> button for the linear and curve settings
menu. The Linear menu is only accessable on lines 1 and 2;
the Curve menu is only accessable on lines 3 through 5.
Linear menu (Img.1)
Select the "A" percent button to set the left (red) line and
the "B" percent button to set the right (blue) line. Use the
<+ or -> keys or press the curved arrow key to reset to
the default value (0%).
Press the "X" or "Y" percent buttons to move the line on
the X or Y axis via the <+ or -> keys. Press the curved
arrow key to reset to the default value (0%).
Move the throttle lever or the steering wheel. The green
line moves horizontally through the diagram.
Curve menu (Img.2)
Point setting step by step:
1. Press the button "ST OFF" to switch to "ST ON".
2. Move the throttle lever or the steering wheel. A green line
moves horizontally through the diagram.
3. Press the +/- key to set a new point. To delete, press the
point to highlight it red and press the +/- key.
4. Set up to a maximum of 5 points.
Point moving step by step:
1. Press the button "ST OFF" to switch to "ST ON".
2. Select the point to be reallocated by moving the steering
wheel or the throttle lever until the point is highlighted red.
3. Select the X-axis or the Y-axis button. Reposition the
point using +/- key.
4. The mixer is not linear and follows the set curve.
BACK
NORMAL
SERVO
ACT
INH
1.
MST SLV SET
2.
3.
4.
5.
INH
INH
INH
ON
NONE
NONE
NONE
NONE
ST
NONE
NONE
NONE
NONE
CH4
>>
BACK
NORMAL
SERVO
ST >> CH3
ACT
0%A
INH
B
X Y
0%
0%
0%
BACK
ACT
NORMAL
SERVO
X-axis
ST >> CH3
T-OFF
POINT ? 0%
IN
Y-axis
ST ON
INH
-100%
OUT
-62%