User Manual
Smart Box (Configuration by Telemetry)
The use of optional smart box supports easy configuration.
When operating in SETTING & DATA VIEW mode in telemetry box, the screen appears as follows.
Smart Box (#33700)
1. ALARM VOLT
It is used for low battery warning program. (Adjustable from 3.5V to 8.0V)
The default value is 3.7V.
2. ALARM TEMP
It is used for receiver’s warning program (Adjustable from 30℃ to 80℃)
The default value is 65℃
3. PERIOD
It is used to set the speed of receiver’s output signal. (Selectable 10msec or 20msec)
4. ALARM EX-VOLT
Selectable auto, 2.0V~24.0V (Default value: Auto)
Detectable from 1.0V to 25.5V (LiPo 4 cell=max 25.2V)
In “Auto” selection, Low voltage warning alarm is activated at 70% of detected voltage when power is
on.
5. ALARM EX-TEMP
Connect Temperature Sensor to Port 4 (T/V Connecter).
Adjustable from 50℃ to 150℃ (Default value: 100℃)
※ If you have a transmitter that does not have the feature setup for temperature, the temperature is
fixed at a specific value.
RECEIVER 0.01 >
>AL RX-V(5.1V) : 3.7V
AL RX-T(+33`c): 65`C
PERIOD : 10ms
AL EX-V( 7.4V): AUTO
AL EX-T( 27`C):100`C