Operation Manual
77
EN
Outdoor temperature compensation (OTC)
For OTC regulation, the starting and end points of the
heating curve are set
They can be set in the installation menu under INST_TyPE
To change the temperatures temporarily, the heating curve
can be shifted by pressing the keys, see manual
override page 79
10
20
30
40
50
60
70
80
90
+20
Outdoor temperature
Supply temperature
+10 0 -10
°C
-20 °C
Starting point
End point
Operating hours (OPT) Displays the operating hours of the room thermostat
(max 99999 hours)
Maintenance (MAN) You can set whether and after how many months a maintenance
message is to be displayed – 6M (6 months), 12M (12 months), 18M
(18 months), 24M (24 months), rST (Reset) or OFF
After the set time has expired, a message appears on the display
Battery level (BAT) The battery level is displayed