Outdoor temperature compensation (OTC)
For OTC regulation, the starting and end points of the
heating curve are set
They can be set in the installation menu under INST_TyPE
To change the temperatures temporarily, the heating curve
can be shifted by pressing the keys, see manual
override page 79
10
20
30
40
50
60
70
80
90
+20
Outdoor temperature
Supply temperature
+10 0 -10
°C
-20 °C
Starting point
End point
Operating hours (OPT) Displays the operating hours of the room thermostat
(max 99999 hours)
Maintenance (MAN) You can set whether and after how many months a maintenance
message is to be displayed – 6M (6 months), 12M (12 months), 18M
(18 months), 24M (24 months), rST (Reset) or OFF
After the set time has expired, a message appears on the display
Battery level (BAT) The battery level is displayed