Operation Manual

75
EN
Algae function (ALG) Sets the algae function: ON or OFF
To prevent the formation of bacteria in the domestic hot water storage
tank during prolonged shutdown periods, the domestic
hot water is heated once a week (Wednesdays, 2:00 o'clock) to 70°C
for one hour
(Only available if a separate domestic hot water storage tank is
present)
Regulation (REG) To select between PID and 2-point regulation (preset: PID)
System reaction (S_R) Sets the heating system reaction
– Fast (FSt): 12 cycles per hour (preset)
– Medium (Med): 6 cycles per hour
– Slow (Slo): 3 cycles per hour
(only available, if regulation (REG) is set to PID)
Differential (DIF) Sets the differential value to between 01°C and 09°C
(only available, if regulation (REG) is set to 2P)
Optimum start (OPS) Sets the optimum start: ON or OFF
(the temperature is reached at the set time)