Operation Manual

50
Operation and conguration
Operating information
Flashing texts signal that an entry is
required If you do not enter anything within
two minutes, the device switches back to
automatic operation
Confirm all entries by pressing OK
Saved settings are stored in the data memory
The histogram shows the programmed
temperature profile
7 – 15°C = shown as one segment
16 – 26°C = one segment represents 1°C
more than 26°C = shown as 12 segments
The device provides two ways of regulating the
room temperature:
Room-temperature-dependent regulation
without outdoor temperature sensor (PID
adjustable, 2-point regulation or optimum start)
Integrated into the control device is a room
temperature sensor, which will take into
account heat sources, such as solar radiation
or stoves
Regulation depending on outdoor temperature
including outdoor temperature sensor (OTC –
outdoor temperature compensation)
See chapter External Inputs; outdoor
temperature sensor"