User's Guide
110
Menu references
Production Setup
Mat/Gam Seq G/M, M/G S Selects the order of the matrix and gamma:
G/M = gamma before matrix;
M/G = matrix before gamma (advised to use when
matching with cameras of other manufacturers)
HDR Mat/Gam Seq G/M, M/G S Selects the order of the HDR matrix and gamma in HDR
mode.
Advanced
G->R 0..99 (50) S Sets Green into Red coefficient (when Matrix is set to
variable).
B->R 0..99 (50) S Sets Blue into Red coefficient (when Matrix is set to
variable).
R->G 0..99 (50) S Sets Red into Green coefficient (when Matrix is set to
variable).
B->G 0..99 (50) S Sets Blue into Green coefficient (when Matrix is set to
variable).
R>B 0..99 (50) S Sets Red into Blue coefficient (when Matrix is set to
variable).
G->B 0..99 (50) S Sets Green into Blue coefficient (when Matrix is set to
variable).
Image Control
Freeze Off, On 2 Switches image freeze on or off. Use to assist off line
setup and configuration.
Reverse Scan
Reverse Scan Off, On 0 Switches Reverse Scan on or off.
Mode Horiz, Vert, Both 0 Selects Reverse Scan mode:
Horiz = the image is flipped horizontally;
Vert = the image is flipped vertically;
Both = the image is flipped both horizontally
and vertically.
Image Shift
Horizontal -20..20 (0) 0 Shifts the image in horizontal direction (in pixels)
Vertical -4..4 (0) 0 Shifts the image in vertical direction (in lines)
Video Mode <list of video modes> 3 Current video mode. Available video modes depend on
camera model, configuration and installed license.
Sensitivity Nom, HiQ, HiSens 3 Sensitivity mode:
HiQ = High quality
Nom = Nominal
HiSens = High sensitivity
Note: Sensitivity mode is not available for high speed
video modes.
Output Mode YCrCb 422, YCrCb 444,
RGB 444
3