User's Guide
149
LDX 100
User’s Guide
DC Power input connector
DC Power output connector
Pin Description
1 GND Pins 1 & 2 are 
bridged
2GND
3 +12 to +17 V Pins 3 & 4 are 
bridged
4 +12 to +17 V
XLR 4-pin male 
connector
(panel view)
CAUTIONS:
input voltage must not exceed 17 V
total input current must be <= 16A
3
2
4
1
Pin Description
1 GND Pins 1 & 2 are 
bridged
2GND
3 +13 to +17 V Pins 3 & 4 are 
bridged
4 +13 to +17 V
XLR 4-pin female 
connector
(panel view)
NOTE: DC Power is not available when the 
camera is locally powered by the DC 
Power input connector.
When more than 4 A current is drawn 
from this connector, the power overload 
indicator (located next to the connector) 
lights.
2
3
1
4