Operation
Description of LED and Digital Display Codes
Note: The audio alarm will sound for five minutes. After five
minutes, the unit will turn off.
Restarting After an AC Output Shutdown
1. Press and hold the unit’s power switch to turn it Off.
2. Remove all AC loads or let the unit cool down for 15 minutes.
3. Press and hold the unit’s power switch to turn it On.
Operating Limits
Power Output
The PurePower 1800 inverter will deliver the following power
continuously, depending on input voltage and ambient temperature.
The inverter will deliver more than 10% of its continuous power
rating for approximately five minutes. The inverter must cool down
for 15 minutes before it can resume operation above its continuous
power rating.
LED Digital Display Description
Green ... Example: 13.5 volts
Green ... Example: 0.25 kW (250 watts)
Red ... Under voltage alarm and/or Under
voltage shutdown
Red ... Over voltage shutdown
Red ... Over load shutdown
Red ... Over temperature shutdown
Red ... Short circuit or output circuit
overheat
Power
a
a.Applies to resistive loads such as incandescent lights.
Output
Current
b
b.Applies to reactive loads such as motors.
Input
Voltage Temperature
PurePower 1800 1800 W 15 A 13 Vdc Ambient
25 °C
(77 °F)