Full Product Manual
8 PurePower 1800 Owner’s Guide
Installation
NOTES:
When planning to install the PurePower 1800 inverter, be sure that
you consider the location and orientation carefully.
The inverter may be used in marine applications beneath the
weather deck that are always dry and protected from prolonged and
sustained exposure to moisture and water. Even with the installation
of additional drip protection such as drip shields
1
, this will not
prevent the entry of dripping water when the inverter is installed in
outside areas of boats such as on the promenade or on the main and
weather decks.
Mount The Inverter
1. Select an appropriate mounting location and orientation. The
unit can be oriented in any way, such as:
• Horizontally on a vertical surface or
• On or under a horizontal surface.
2. Hold the inverter against the mounting surface and mark the
positions using the mounting flanges as guide.
3. Pilot-drill the four mounting holes.
4. Fasten the inverter to the mounting surface using corrosion-
resistant hardware sized #10.
Protected
from
battery
gases
Do not mount the inverter where it will be exposed to gases
produced by the batteries. These gases are very corrosive and
prolonged exposure will damage the inverter.
1.Drip shields order part number 808-1050.
ELECTRICAL SHOCK HAZARD
Do not install in an open cockpit or on the weather deck of a
marine vessel.
Failure to follow these instructions can result in minor or moderate
injury.
DC connections should NOT
point up or down.
REMOTE
FAULTPOWER
REMOTE
FAULTPOWER
PurePower 1800.book Page 8 Monday, December 12, 2016 5:06 PM