Grape Solar GS-MPPT-ZENITH Series Charge Controller User Manual *Grape Solar reserves the rights to modify these specifications without notice. Rev 2020.04.
1. Warnings and Tools Icon Chart Icons Name ~ ~ High Voltage High Temperature Environmental Hazard Wire Cutter Multimeter Anti-static Glove Electrical Tape Screwdriver Rev 2020.04.23 Description High voltage device. Installation should be performed by an electrician. This device will produce heat. Mount device away from other items. Electronic Equipment. Do not put in landfill. A wire cutter is needed for cutting and stripping wires prior to connection.
2. Safety Tips Review this manual thoroughly before attempting installation. Beware of any nearby electrical equipment that may interfere with installing this device. Solar panels can generate high voltages and currents, make sure your solar panels are completely covered from sunlight during installation. It is recommended that installation be performed by a qualified electrician.
3. Product Features Thank you for choosing Grape Solar. This MPPT solar charge controller is a device for solar charge regulation and direct current output load control. This device is mainly used in small and medium sized o -grid solar power systems.
4. Device Diagram GS-MPPT-ZENITH-40A & 60A 1 8 2 9 3 # 4 Description 5 6 # 7 Description 1 LCD Display Screen 6 DC Load Terminals 2 Function Key ([SET], [UP], [DOWN], [ESC]) 7 RS485 Communication Port 3 External Temperature Sensor Terminal 8 LED Indicator (PV, BAT, LOAD, FAULT) 4 Solar Terminals 9 Installation Mounting Holes 5 Battery Terminals Rev 2020.04.
5. Mounting Instruction >100mm >200mm cold air Step1: Find a cool,dry and Step 2:Mark the controller's weather safe location for mounting holes on the installation. mounting surface Step 3:Drill holes in the marked Step 4:Insert pilot screws in mountiong hole location the mounting hole φ5 φ10 Step 5:Fasten the controller Step 6:Continue to wire battery, into the pilot screws solar,DC load and other accessories to the controller Rev 2020.04.
6. Wire Connection Sequences Temperature Sensor Communication Module During installation of your MPPT controller, please follow the order of connection below: 1. Connect the positive battery wire followed by the negative battery wire. 2. Make sure your solar panels are fully covered to prevent electrical shock. Connect the positive solar array output wire followed by the negative solar array output wire. 3. Connect DC load wires to the DC load output (if applicable). 4.
7. LED Light Signal Interpretation Chart LED Name LED Display O PV BATTERY FAULT Solar Input Not Charging ○! *PV LED is generally o during nighttime.
8. LED Flash Rhythm Chart Flash Status Indication Description On Steady On LED light on. O On O LED light o . O On Fast Flash O LED light blinks at frequency of 2Hz (twice every second). On LED light blinks at frequency of Slow Flash 0.5Hz (once every two seconds). O On LED light blinks for 0.1 second Single Flash after every 2 seconds. O On LED light blinks for 0.1 second Double Flash twice after every 4 seconds. O Rev 2020.04.
9. LCD Display Interface Overview Active Functions Display Unit Charge Status 10. LCD Display Interface Display Section Display Layout Charge Status Charge Mode & Parameter Active Functions Rev 2020.04.
.Status Information Status Icon Indication Solar Charge Indication DC Load Indication Status Flowing O Flowing O Description Solar Power Charging Battery Solar Power Not Charging Battery DC Load Drawing Power DC Load O MPPT Charge Mode Steady On Boost Charge Mode Charge Mode Float Charge Mode Voltage Setting Over Discharge Voltage Settings O Not Charging On Setting Charge Voltage O Charge Voltage Has Been Set On Setting Discharge Voltage O Discharge Voltage Has Been Set Steady On Solar I
. Key Functionality Chart Function Key Function System Mode Input Input Function View Mode Short Press Enter SET mode View Mode Short Press View Previous Page View Mode Short Press View Next Page View Mode Short Press DC Load On/O (Manual Control Program Only) System Mode Input Input Function Long Press Save Data & Exit SET Mode Short Press Next Setting Set Mode Short Press Increase Parameter Value Set Mode Short Press Decrease Parameter Value Set Mode Short Press Exit SET
. LCD Display Rules & Cycles Pre start-up display cycle when the MPPT controller turns on, this usually last several seconds while controller detects operating environment. LCD Screen Display Cycle Charging Voltage PV Amperage Charging Watt Battery Voltage Charging Amperage Battery Capacity Load Amperage Error Code Controller Temperature Load Mode Load Watt The battery voltage view will be displayed by default. Use the up and down arrow keys to cycle through di erent views.
Setting Battery Mode Enter SET mode by pressing the Setting key in any view page other than Load Mode. Use the up and down arrow keys to select battery mode, then long press Setting key to save. Abbreviations FLD Flooded Battery SEL Sealed/AGM Battery GEL Gel Battery LI USER Rev 2020.04.23 Battery Types Description Auto-recognition with default parameters set for each type of batteries. Lithium Battery Some parameters can be customized. Advanced User Mode Most parameters can be customized.
Advanced Battery Settings In Lithium or User mode, short press the Setting key again to cycle through each parameter view. Use the up and down arrow key to adjust parameter value, then long press Setting key to save.
Advanced Battery Settings Enter Load SET Mode by pressing the Setting key in Load Mode view only. Use the arrow key to cycle through load modes before long pressing SET to save and exit. Short pressing SET will exit without saving. Setting Load Mode Load Mode View 【SET】 MPPT long【SET】press save and exit setup short【ESC】press exit without saving Mode 0 1~14 Definition Daylight Auto-Control Daylight On/Timer O Description DC load turns on when daylight is detected.
14. Error Code Chart Code Error E00 No Error E01 Battery Over-discharged E02 Battery Over-voltage E04 Load Short Circuit E05 Load Overload E06 Overheating Description & Quick Troubleshoot No action needed. Battery voltage is too low. DC load will be turned o until battery re-charges to recovery voltage. Battery voltage has exceeded controller limit. Check battery bank voltage for compatibility with controller. DC load short circuit. DC load power draw exceeds controller capability.
Controller Specification The variable “n” is adopted as a multiplying factor when calculating parameter voltages, the rule for “n” is listed as: if battery system voltage is 12V, n=1; 24V, n=2; 36V, n=3; 48V, n=4. For example, the equalize charge voltage for a 12V FLD (Flooded) battery bank is 14.8V*1=14.8V. The equalizing charge voltage for a 24V FLD (Flooded) battery bank is 14.8V*2=29.6V. Parameter Value Model No.
15. Product Dimension GS-MPPT-ZENITH-40A 245mm / 9.7inch 180mm / 7.1inch Product Dimension: 245*180*82.5mm / 9.7*7.1*3.3inch Installation Area Dimension: 226*138mm / 8.9*5.4inch Installation Hole Size: φ 5mm&φ 10mm / φ 0.2inch &φ 0.4inch Connection Socket Size: 7.5*7.5mm / 0.3*0.3inch 138mm / 5.4inch 4*φ5mm / 4*φ0.2inch 82.54mm / 3.3inch 4*φ10mm / 4*φ0.4inch 226mm / 8.9inch GS-MPPT-ZENITH-60A 201mm / 8.3inch 280.1mm / 11.8inch Product Dimension: 280*210*90mm / 11*8.3*3.