Full Product Manual

EZ Pitched Roof System
29 of 30
Ground Wire Attachment
Ground Lug Installation
Rail End Covers
Rail End Covers can be attached to the
mounting rails as shown.
One Rail per row of panels should have a
Ground Lug for fastening the ground conductor
to the array. The Ground Lug is mounted on the
top or side of the Rail using a special 1/4” T-
Bolt, Grounding Spacer, and Flange Nut.
Grounding Lugs K10179-001, and detailed
installation document D10003 are available from
SunModo separately.
One Rail per row of panels should have
a Ground Lug for fastening the ground
The picture shows a grounding lug mounted on
one Rail per row of panels, and a #6 solid
copper grounding wire connecting the Ground
Lugs to the building ground per NEC 690.47.