Installation Guide

EZ Roof Mount
Attachments
9 of 14
Torque Values:
These values must be adhered to for mechanical strength. It is required that a torque wrench be used
to measure the bolt torque during final assembly, and it is recommended that anti-seize compound,
such as Permatex, be applied to the screw threads.
Note: We strongly recommend against the use of an impact wrench except for the installation of the
Lag Bolts.
Caulk gun and silicon sealant
ChemLink M1 (or equivalent) for wood and
composite roofs.
ChemLink DuraLink (or equivalent) for metal roofs.
Tape measure
Saws for cutting aluminum posts and rails as necessary
Other items that can be useful:
Chalk or roofers marker to layout roof.
Adaptor for 3/8 socket to drill chuck.
#3 Phillips bit
Hardware
Torque
1/4” Bolts and Hex Flange Nuts
7.5 ft. lbs.
1/4 X 3” Decking Fastener
As Required
5/16 X 4” Lag Bolt
25 ft. lbs.
3/8” Bolts and Hex Flange Nuts
15 ft. lbs.
3/8” T-Bolts and Hex Flange Nuts
15 ft. lbs.
Mid or End Clamp, 1/4-20 Female Standoff
with 7/16” Hex Head Collar Nut
7.5 ft. lbs.
Ground Lug: 1/4” Flange Nut with 7/16 hex drive head
7.5 ft. lbs.
Ground Lug: 1/4” setscrew with1/8 Allen drive
4.2 ft. lbs. (50 in. lbs.)
HEX Cap: 1-1/16” socket
15 ft. lbs.