Full Product Manual
EZ Pitched Roof System
18 of 30
Torque Values for Pitched Roof System
These values must be adhered to, both for mechanical strength and to insure the performance
of the integral grounding and bonding features. It is required that a torque wrench be used to
measure the bolt torque during final assembly, and it is recommended that anti-seize
compound be applied to the screw threads.
Hardware
Torque lbs.
1/4-20 Bolts and Hex Flange Nut
7.5 ft. lbs.
1/4-20 Ground Lug, Flange Nut with 7/16 Hex Head
7.5 ft. lbs.
1/4-20 Ground Lug, Setscrew with 1/8 Allen drive.
4.2 ft. lbs. (50 in. lbs.)
1/4-20 Mid or End Clamp, Female Standoff with 7/16”
Hex Head Collar Nut
7.5 ft. lbs.
5/16 Lag Bolts
25 ft. lbs.
3/8-16 Bolts and Hex Flange Nuts
15 ft. lbs.
3/8-16 T-Bolts and Hex Flange Nuts
15 ft. lbs.
1-1/16” Hex Cap
15 ft. lbs.