Application Guide
P a g e  |  98   
DP750/DP720 Administration Guide 
Version 1.0.3.37 
4.  Update the change by clicking the "Save and Apply" button. 
Notes:   
-  The DP720 handset detects automatically if the base station is upgraded with a new firmware and 
display on the LCD a prompt message inviting the user to initiate the upgrade, more over under 
the Web GUI of the base station DP750  Status  DECT Status  Handset Status, appears an 
Upgrade All button once the base detect that several registered handsets are using an old 
firmware version so the user could upgrade all handsets by pressing Upgrade All button. 
•  After downloading firmware, DP720 screen will be black and red LED will be blinking showing that 
firmware upgrade process is ongoing. 
DP750/DP720 Provisioning 
Configuration File Download 
Grandstream  SIP Devices can be configured via the  Web Interface as well as  via a Configuration File 
(binary or XML) through TFTP or HTTP/HTTPS. The Config Server Path is the TFTP or HTTP/HTTPS 
server path for the configuration file. It needs to be set to a valid URL, either in FQDN or IP address format. 
The Config Server Path can be the same or different from the Firmware Server Path. 
A configuration parameter is associated with  each particular field in  the web configuration page. A 
parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric 
numbers. i.e., P2 is associated with the "New Password" in the Web GUIMaintenanceWeb/SSH Access 
pageAdmin Password. For a detailed parameter list, please refer to the corresponding firmware release 
configuration template. 
When the DP750 boots up or reboots, it will send a request to download a file named "cfgxxxxxxxxxxxx” 
followed  by  a  configuration  XML  file  named  "cfgxxxxxxxxxxxx.xml",  where  "xxxxxxxxxxxx"  is  the  MAC 
address  of  the  phone,  i.e.,  "cfg000b820102ab"  and  "cfg000b820102ab.xml".  If  the  download  of 
"cfgxxxxxxxxxxxx.xml" file is not successful, the provision program will download a generic cfg.xml file. The 
configuration file name should be in lower case letters. 
For more details on XML provisioning, please refer to: 
http://www.grandstream.com/sites/default/files/Resources/gs_provisioning_guide.pdf 
Handset Provisioning 
To  configure  the  handset provisioning,  please browse  the  base  station  Web  GUI  at  Maintenance  
Provisioning. This is the same page used for base station provisioning. Handset shares the settings of base 
station provisioning in the field in the red rectangle, and has its own settings in the blue rectangle. After 
enabled Handset Config Upgrade, need reboot the DP750 to take effect. 