User's Manual
Firmware Version 1.0.0.5 
UCM6510 IP PBX User Manual 
Page 77 of 192 
The following dialog shows the digital port configuration parameters. Click on "Show Advanced Options" to 
view more options. 
Table 25: Ports Config/Digital Hardware: Edit Digital Ports 
Span Type 
Select the digital channel mode "E1", "T1" or "J1" (J1 is TBD). 
Clock 
All  T1/E1  spans  generate  a  clock  signal  on  their  transmit  side.  The 
parameter determines whether the clock signal from the far end of the 
T1/E1 is used as the master source of clock timing. If the far end is used 
as the master, the PBX system clock will synchronize to it. 
  Master: The port will never be used as a source of timing. This is 
appropriate when you know the far end should always be a slave to 
you. 
  Slave: The equipment at the far end of the E1/T1 link is the preferred 
source of the master clock. 
Signaling 
If  the  far  end  is  set  to  "PRI_NET",  this  option  should  be  set  to 
"PRI_CPE" on the UCM6510. 
LBO 
The line build-out (LBO) is the distance between the operators and the 
PBX. Please use the default value 0dB unless the distance is long. 
RX Gain 
Configure the RX gain for the receiving channel of digital port. The valid 
range is from -24dB to +12dB. 
TX Gain 
Configure the TX Gain for the transmitting channel of digital port. The 
valid range is -24dB to +12dB. 
Codec 
Select alaw (PCMA) or ulaw (PCMU). The default code is alaw for E1 
and ulaw for T1. 
Advanced Options 
Switch Type 
Select switch type. 
  euroisdn: EuroISDN (common in Europe) 
  national: National ISDN    type 2 (common in the US) 
  dms100: Nortel DMS100 
  4ess: AT&T 4ESS 
  5ess: Lucent 5ESS 
  ni1: old national ISDN type 1 
  qsig: Q.SIG 
Coding 
For T1, select "ami" or "b8zs"; for E1, select "ami" or "hdb3". 
CRC 
For E1, select whether to use CRC4 or CRC6. For J1 (pending), CRC6 