User's Guide
P a g e | 39 
HT81x User Guide 
In  addition,  when  the  field  “Check  New  Firmware  only  when  F/W  pre/suffix  changes”  is  set  to  “Yes”, 
thedevice will only issue firmware upgrade request if there are changes in the firmware Prefix or Postfix. 
Managing Firmware and Configuration File Download 
When  “AutomaticUpgrade”isset“Yes,every”theautocheckwillbedoneintheminute  specified  inthis 
field.Ifsetto“dailyathour(0-23)”,  Service  Provider  canuseP193(AutoCheckInterval)tohavethe 
devicesdoadailycheckatthehour  set  inthis  fieldwith  either  FirmwareServerorConfigServer.Ifsetto 
“weeklyonday(0-6)”theautocheck  will  bedoneon  thedayspecifiedin  this  field.Thisallowsthedevice 
periodically  checkifthereareanynewchangesneedtobetakenonascheduledtime.Bydefining 
differentintervalsinP193fordifferentdevices,ServerProvidercan  spreadtheFirmwareorConfiguration 
FiledownloadinminutestoreducetheFirmwareorProvisioningServerloadatanygiventime 
Configuration File Download 
Grandstream SIP Devices can be configured via the Web Interface as well as via a Configuration File 
(binary or XML) through TFTP or HTTP/HTTPS. The Config Server Path is the TFTP or HTTP/HTTPS 
server path for the configuration file. It needs to be set to a valid URL, either in FQDN or IP address format. 
The Config Server Path can be the same or different from the Firmware Server Path. 
A  configuration  parameter  is  associated  with  each  particular  field  in  the  web  configuration  page.  A 
parameter consists of a Capital letter P and 2 to 3 (Could be extended to 4 in the future) digit numeric 
numbers.  i.e.,  P2  is  associated  with  the  "New  Password"  in  the  Web  GUI->Maintenance->Web/SSH 
Access page->Admin Password. For a detailed parameter list, please refer to the corresponding firmware 
release configuration template. 
When  the  HT81X  boots  up  or  reboots,  it  will  send  a  request  to  download  a  file  named 
"cfgxxxxxxxxxxxx”followed  by  a  configuration  XML  file  named  "cfgxxxxxxxxxxxx.xml",  where 
"xxxxxxxxxxxx" is the MAC address of the phone, i.e., "cfg000b820102ab" and "cfg000b820102ab.xml". If 
the  download  of  "cfgxxxxxxxxxxxx.xml"  file  is  not  successful,  the  provision  program  will  download  a 
generic cfg.xml file. The configuration file name should be in lower case letters. 
For more details on XML provisioning, please refer to: 
http://www.grandstream.com/sites/default/files/Resources/gs_provisioning_guide.pdf 