Advanced User configuration includes the end user configuration and the advanced configurations including:
a) SIP configuration, b) Codec selection, c) NAT Traversal Setting and d) other miscellaneous configuration.
HT701 each FXS SIP account has its own configuration page. Their configurations are identical.
T
ABLE 9: ADVANCED SETTINGS
Admin Password
This contains the password to access the Advanced Web Configuration page. This field is
case sensitive. Only the administrator can configure the “Advanced Settings” page.
Password field is purposely left blank for security reasons after clicking update and saved.
The maximum password length is 25 characters.
Layer 3 QoS
This field defines the layer 3 QoS parameter which can be the value used for IP
Precedence or Diff-Serv or MPLS. Default value is 12.
Layer 2 QoS Value used for layer 2 VLAN tag. Default setting is blank.
STUN Server
IP address or Domain name of the STUN server.
Keep-alive interval
This parameter specifies how often the HT701 sends a blank UDP packet to the SIP server
in order to keep the “hole” on the NAT open. Default is 20 seconds. Minimum value is 20
seconds.
Use STUN to detect
network connectivity
Use STUN keep-alive to detect WAN side network problems. If keep-alive request does
not yield any response for configured number of times, the device will restart the TCP/IP
stack. If the STUN server does not respond when the device boots up, the feature is
disabled.
Firmware Upgrade and
Provisioning
Enables HT701 to download firmware or configuration file through either the TFTP, HTTP
or HTTPS server.
Via TFTP Server This is the IP address of the configured TFTP server. If selected and it is non-zero or not
blank, the HT701 retrieves the new configuration file or new code image from the specified
TFTP server at boot time. After 5 attempts, the system will timeout and will start the boot
process using the existing code image in the Flash memory. If a TFTP server is
configured and a new code image is retrieved, the new downloaded image is saved into
the Flash memory.
Note: Please do NOT interrupt the TFTP upgrade process (especially the power supply) as
this will damage the device. Depending on the local network, this process can take up to
15 or 20 minutes.
Via HTTP / HTTPS
Server
The URL for the HTTP/HTTPS server used for firmware upgrade and configuration via
HTTP.
For example, http://provisioning.mycompany.com:6688/Grandstream/1.0.0.67“:6688” is
the specific TCP port where the HTTP or HTTPS server is listening; it can be omitted if
using default port 80.
Note: If Auto Upgrade is set to No, HT701 will only do HTTP/HTTPS download once at
boot up.
Firmware Server Path
IP address or domain name of firmware server.
Config Server Path
IP address or domain name of configuration server.
XML Config File
Password
The password used for encrypting the XML configuration file using OpenSSL.
This is required for the phone to decrypt the encrypted XML configuration file.
HTTP/HTTPS User
Name