SIP TLS Private Key 
Password 
User specify password to protect the private key above. 
ACS URL 
User specify the Auto Configuration Server’s URL (TR-069 protocol) 
ACS Username 
User specify the ACS Username 
ACS Password 
User specify the ACS password 
Periodic Inform 
Enable 
Default is No. If set to YES, device will send inform packets to the ACS 
Periodic Inform 
Interval 
Frequency that the inform packets will be sent out to the ACS 
Connection Request 
Username 
Set a user name for the ACS to connect to this device 
Connection Request 
Password 
Set a password for the ACS to connect to this device 
Connection Request 
Port 
Set a port number for the ACS to connect to this device, default is 7547 
CPE SSL Certificate 
Configure the SSL authentication of Customer-premises equipment 
CPE SSL Private Key 
Configure the SSL Private Key of Customer-premises equipment 
System Ring Cadence 
Configuration option is set ring cadence on all FXS ports for all incoming calls. (Syntax: 
c=on1/off1-on2/off2-on3/off3(only 3 cadences maximum)) Default is set to c=2000/4000; 
(US standards) 
Call Progress Tones 
Using these settings, users can configure tone frequencies and cadence according to 
their preference. By default they are set to North American frequencies. Configure these 
settings with known values to avoid uncomfortable high pitch sounds. ON is the period of 
ringing (“On time” in ‘ms’) while OFF is the period of silence. In order to set a continuous 
tone, OFF should be zero. Otherwise it will ring ON ms and a pause of OFF ms and then 
repeat the pattern. 
Example configuration for N.A. Dialtone: 
f1=350@-13,f2=440@-13,c=0/0; 
Syntax: f1=freq@vol, f2=freq@vol, c=on1/off1-on2/off2-on3/off3; [...] 
(Note: freq: 0 - 4000Hz; vol: -30 - 0dBm) 