User's Manual
STUN Server
IP address or Domain name of the STUN (Simple Traversal of UDP through NATs) server. 
Firmware 
Upgrade & 
Provisioning
This radio button will enable GXW410x to download firmware or configuration file through either 
TFTP or HTTP.
Via TFTP Server
If selected, the GXW410x will attempt to retrieve new configuration file or new code image from the 
specified TFTP server at boot time. It will make up to 5 attempts before timeout and then it will start 
the  boot  process  using  the   existing code  image  in  the  Flash  memory.  If   a TFTP  server  is 
configured and a new code image is retrieved, the new downloaded image will be verified and then 
saved into the Flash memory.
Note: Please do NOT interrupt the TFTP upgrade process (especially the power supply) as this will 
damage the device.  Depending on the network environment this process can take up to 25 or 30 
minutes.
Via HTTP Server
The URL for the HTTP server used for firmware upgrade and configuration via HTTP. 
For example, http://provisioning.mycompany.com:6688/Grandstream/
Here “:6688” is the specific TCP port that the HTTP server is listening at, it can be omitted if using 
default port 80.
Note: If Auto Upgrade is set to No, GXW410x will only do HTTP download once at boot up.
Firmware Server 
Path
IP address or domain name of firmware server.
Config Server 
Path
IP address or domain name of configuration server.
Firmware File 
Prefix
Default is blank.  If configured, GXW400X will request firmware file with the prefix.  This setting is 
useful for ITSPs. End-user should keep it blank. 
Firmware File 
Postfix
Default is blank. End-user should keep it blank.
Config File 
Prefix
Default is blank. End-user should keep it blank.
Config File 
Postfix
Default is blank. End-user should keep it blank.
Allow DHCP 
Option 66 to 
override server
Default value is No. If set to Yes, configuration file will originate from the DHCP server.
Automatic 
Upgrade
Choose Yes to enable automatic upgrade and provisioning.  In “Check for new firmware every” 
field, enter the number of minutes to enable GXW410x to check the server for firmware upgrade or 
configuration. When set to No, GXW410x will only do upgrade once at boot up. Other options are: 
“ Always check for New Firmware.” 
“ Check New Firmware only when F/W pre/suffix changes”
“ Always skip the Firmware check”
Authenticate 
Conf File
If set to Yes, configuration file is authenticated before acceptance. This protects the configuration 
from an unauthorized change. 