Selects the level of logging for syslog. The default setting is None. It means send no
syslog.
The 4 levels from high to low are: DEBUG, INFO, WARNING and ERROR.
Syslog messages are sent based on the following events:
product model/version on boot up (INFO level);
NAT related info (INFO level);
sent or received SIP message (DEBUG level);
SIP message summary (INFO level);
inbound and outbound calls (INFO level);
registration status change (INFO level);
negotiated codec (INFO level);
ethernet link up (INFO level);
SLIC chip exception (WARNING and ERROR levels);
Memory exception (ERROR level).
Figure 157 GXV3275 Web GUI Maintenance-Logcat
Table 28 Maintenance/Logcat Parameters