User's Manual
Grandstream Networks, Inc. DP715-US/DP710-US User Manual Page 7 of 43
Firmware 0.0.0.8 Last Updated: 03/2012
Table 2: Definitions of the DP71X Connectors
DC 6V
Power adapter connection
LAN Port (RJ-45)
Connect to the internal LAN network. (DP715_US Only)
RESET
Factory Reset button: Press for 7 seconds to reset factory default settings.
DP715_US Only)
There are four (4) LED buttons that help you manage the status of your DECT Base DP715.
Table 3: Basic Definitions of the DP715 LEDs Pattern
LEDs
POWER LED
Indicates Power. Remains ON when power is connected
Network
Indicates Access to the Network. Remains ON while there is Access to the Network
Registered
Indicates if the accounts are registered
Call
Indicate status of active calls.
Table 4: Advanced Definitions of the DP715_US LEDs Pattern
Patten
Number
Condition LED LED Behavior
LED-01
Device has normal power Power ON
LED-02 Power Error: Power is removed from the device or power
supply with improper voltage is plugged in
Power OFF
LED-03
Device has normal LAN connection and has obtained an
IP address
Network ON
LED-04
Link Down
Note : This is the default state while the device is booting.
Network Blink ( 1s on/ 1s off ).
LED-05
Link Up but no IP Address Network Blink ( .25s on/ .25s off )
LED-06
All configured SIP accounts are registered Registered ON
LED-07
SIP accounts are in the process of registering Registered Blink ( 1s on/ 1s off )
LED-08
Device is booting, application has not started. Registered Blink ( .25s on/ .25s off )
LED-09
Registration Error - ANY SIP account experiences
registration failure.
Registered 0.25sec ON/ 0.25sec OFF
LED-10
Call is active. Any DECT handset is in an active call with
an external line.
Call ON
LED-11
No active call. Call OFF