Assembly Instructions
5
INSTALLATION AND ASSEMBLY
ALWAYS unplug this fireplace heater before assembly, cleaning, or relocating.
Failure to do so could result in electric shock, fire, or personal injury.
i
STEP 1: Find a safe location.
Minimum clearance
on each side: 20".
Minimum clearance below:
20". (Wall mount only).
Minimum clearance above:
39.5".
Minimum clearance from the front:
36".
Choose a location near an outlet so
an extension cord is not required.
DO NOT position the unit
directly below a power outlet.
The Drywall Anchors(C) included with this fireplace are for use ON LY with a wood
framed wall covered in drywall (sheet rock). For concrete walls, cinder blocks, or
other wall types, consult a professional for the best attachment methods.
NOTICE
Minimum 39.5"
Minimum 20"
(Wall mount only)
20" 20"
1
STEP 2: Locate the wall studs using an electronic stud finder.
STEP 2a: If two studs are available, drill 1 hole in each using 1/4” drill bit. Drill third and
final hole in between the two studs.
STEP 2b: If only 1 stud is available, use stud as center and drill 2 holes on either side of stud
(each hole should be 8” apart from one another).
STEP 3: With a hammer, tap the Drywall Anchors(C) carefully into the hole(s) until they are flush
with the drywall surface. Use care to avoid damaging the drywall with the hammer.
2
Studs
Drywall Anchors(C)
2a 2b
Two Studs
One Stud
8"
8"
8"
8"
3
Drywall Anchors(C)
ALWAYS make sure the unit is unplugged before beginning assembly! NEVER move or
clean the heater while it is plugged in.
i