K3X EN QUICK START GUIDE PACKAGING 1 x 220 V/12 VDC 1A mains adapter.
KEYBOARD & DISPLAY LCD DISPLAY Displays the weight onto the load receptor. Unit of measurement in which the weight is indicated. Stable weight reading: There is a weight on the platform that is not fluctuating. Intermittent or switched off to indicate that there is movement in the scale. Negative sign. This reading may be negative if a tare is activated or to indicate a problem when setting it to zero. Indicates net weight. The net weight is the actual weight on the scale minus the tare.
KEYBOARD & DISPLAY On / Off. Press once to switch the indicator on. Hold the key down for 2 seconds to switch off the terminal. Esc / Menu. It enters the menu settings mode. When already into the settings menu mode, escapes to the previous menu option or back to the weighing mode. High Resolution. Activates the high-resolution mode. One more digit is added to the weight value for 4 seconds. High / Low limits: activates / deactivates the checkweigher mode. ).
SCALE SETTINGS – MENU OPTIONS For access the settings menu press the Esc / M key. ¿ validate the current setting / moves to the next digit when editing a numeric value ¿¿ validate a manually input value. ESC Returns to the menu’s previous level without making any change. ß à change to the next / previous option. ¯ changes between the different values that can be assigned to a specific option.
SCALE SETTINGS – MENU OPTIONS FILt ½ ½ ½ ½ ½ ½ ½ ¯ D Out ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ½ ¯ tlu ½ ¯ n Lot ¯ INFO ¿ LEUEL ¯ LIVES ¯ Not-F ¯ WSPEEd ¯ O-rAtE ¿ FiL-1 … Fil-8 Filter level ¿ On « OFF • Additional filter for weighing livestock ¿ On « OFF • Motion filter(ON/OFF) ¿ 50SPS « 12SPS Changes AD/C sampling speed ¿ NOdE ¯ tESt ¯ h-L ½ ½ ½ ¯ dOSI ¿ dOSI ¿ T 01 … T 20 ¿ 00000 ¿ Frequency for sending weight information to the terminal ¿ 000000 ¿¿ Digital output mode « ChECk•
SCALE CALIBRATION At the SCAlE menu you will find the settings needed to define and adjust the measurement scale of the instrument: Measurement unit, maximal capacity, scale interval (division), decimal point, as well as different options related to the operation of the auto-zero device. Access to these configuration options is reserved for technical personnel and is protected by a keyword to avoid accidental changes that would cause the instrument to malfunction.
TABLE OF GEOGRAPHICAL ADJUSTMENT VALUES Elevation above sea level in metres Geographical latitude in the northern or southern hemisphere in degrees and minutes.
CONNECTIONS Xtrem scale module PIN No. PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 SIGNAL +Vcc TxD RxD Not connected GND RS-232 serial interface PIN No. PIN 4 PIN 5 PIN 6 SIGNAL +Vcc TxD RxD MORE INFORMATION Download the full manual from the following link: https://gram-group.com/wp-content/uploads/2022/02/MU_K3X_V6_001_ENG.pdf Gram Precision S.L. Travesía Industrial, 11 · 08907 Hospitalet de Llobregat · Barcelona (Spain) Tel. +34 902 208 000 · +34 93 300 33 32 Fax +34 93 300 66 98 comercial@gram.es www.