User guide
8. Installation
PNEG-1276 Top Dry Autoflow Construction Manual 24', 30' and 36' 41
Flashing Bolt Installation
Install the eave flashing bolts (5/16" x 1-1/4") through the sidewall and tighten first nut. Note at the vertical
sidewall seams, one bolt is turned around to avoid interference with eave flashing. (See Figure 8H.)
Figure 8H
Eave Flashing Installation
Install the eave flashing centered on the floor sheet (1 per) with the bent edge towards the sidewall install
a fender washer (S-3671) and nut. Screw the flashing to the flashing angle at the dump hopper opening
with five (5) #10 self-drilling screws (S-280) and screw the flashing pieces together where they overlap
with three (3) #10 self-drilling screws (S-280). (See Figure 8I below and Figure 8J on Page 42.)
Figure 8I
Left bolt on the each vertical sidewall seam level
with the eave flashing bolts (as viewed from
inside the bin) is to be installed bolt in, nut out,
as shown in Figure 8H.
Flashing Attachment
1) Sidewall
2) Flashing (TD-100648)
3) Floor sheet
4) 5/16" x 1-1/4" Bin bolt
Note that there is a nut in between the
sidewall sheet and the flashing sheet.