12. Inverted âTâ Foundation 2.66" Outside Stiffened Commercial Tanks
PNEG-318 Concrete Foundation Recommendations for GSI Grain Bins 57
Diameter of Bin: 18'
Soil Bearing Capacity: 3000 PSF
Ring # 12 14 16 18
A 1'-0" 1'-0" 1'-0" 1'-0"
B 1'-10" 2'-3" 2'-8" 3'-2"
C 9'-10" 9'-10" 9'-10" 9'-10"
D 10'-1" 10'-3" 10'-5" 10'-8"
M 5 #4's 5 #4's 5 #4's 5 #4's
N 2 #5's 3 #5's 3 #5's 3 #5's
P #5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c
Rerod
#4 (ft.) 1700 1700 1700 1700
#5 (ft.) 300 300 400 400
#6 (ft.) 0 0 0 0
Cu. Yds.
Concrete
Footing 4 5 6 7
Wall 10 10 10 10
Floor 5 5 5 5
Total 1 9 20 21 22
Diameter of Bin: 21'
Soil Bearing Capacity: 3000 PSF
Ring # 12 14 16 18
A 1'-0" 1'-0" 1'-0" 1'-0"
B 1'-11" 2'-4" 2'-10" 3'-5"
C 11'-4" 11'-4" 11'-4" 11'-4"
D 11'-8" 11'-10" 12'-0" 12'-3"
M 5 #4's 5 #4's 5 #4's 5 #4's
N 2 #5's 3 #5's 3 #5's 4 #5's
P #5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c #5 @ 14" c/c
Rerod
#4 (ft.) 2100 2100 2100 2100
#5 (ft.) 300 500 400 500
#6 (ft.) 0 0 0 0
Cu. Yds.
Concrete
Footing 5 6 7 9
Wall 12 12 12 12
Floor 6 6 6 6
Total 2 3 24 25 27