Accessories PNEG-1924 Owner manual
135 ft Diameter Bin
Figure 1-10 A-frame installation sequence and temperature cable locations for 135 ft diameter bin
A
12.3 ft radius location C 55.4 ft radius location
B 32.2 ft radius location
Table 1-7 Starting lengths for temperature cables for 135 ft diameter bins
Length from the center collar
None
Length from 12.3 ft diameter location 318.8 in. (80.98 m)
Length from 32.2 ft diameter location 239.4 in. (60.81 m)
Length from 55.4 ft diameter location 67.9 in. (17.25 m)
The temperature cable lengths in the chart above are the distances from where the temperature cable
attaches to the rafter or the center collar to the top ring. To calculate the correct temperature cable length,
add 32 inches for each bin ring to the starting length. Temperature cables must terminate above any
unload equipment and be secured in place with twine. DO NOTallow cables to become tangled in unload
equipment.
Pneg-1924 11