Guidelines for Temperature Cables on 40-Series Bins PNEG-1924 Version 1.
All information, illustrations, photos, and specifications in this manual are based on the latest information available at the time of publication. The right is reserved to make changes at any time without notice.
1 Temperature Cable Guidelines for 40–Series Bins Equipped with the Z-Tek™ ™ Roofing System. Temperature cable brackets are provided by GSI as standard equipment on all 40–Series Bins equipped with the Z-Tek™ roofing system. GSI supplied temperature cable brackets are the only approved method for support of any temperature/moisture cables. All temperature cable brackets must be installed at the specified locations as shown in this document.
Figure 1-2 Typical Center Collar Installation (Where Applicable) C Supplier quick link D Center collar temperature cable hole Figure 1-3 Starting Lengths for Temperature Cables A Length from center collar C Rafter radius 2 B Rafter radius 1 D Rafter radius 3 NOTE: Starting lengths for temperature cables are measured from the temperature cable bracket on the rafter to the top of the top ring.
60 ft Diameter Bin Figure 1-4 A-frame installation sequence and temperature cable locations for 60 ft diameter bin A 3 ft radius location (center collar) B 20 ft radius location Table 1-1 Starting lengths for temperature cables for 60 ft diameter bins Length from the center collar 179.80 in. (45.67 m) Length from 20 ft diameter location 58.1 in. (14.
72 ft Diameter Bin Figure 1-5 A-frame installation sequence and temperature cable locations for 72 ft diameter bin A 9.3 ft radius location B 26 ft radius location Table 1-2 Starting lengths for temperature cables for 72 ft diameter bins Length from the center collar None Length from 9.3 ft diameter location 179.2 in. (14.76 m) Length from 26 ft diameter location 59.6 in. (15.
5 ft Diameter Bin Figure 1-6 A-frame installation sequence and temperature cable locations for 75 ft diameter bin A 5 ft radius location (center collar) B 11.6 ft radius location C 26.3 ft radius location Table 1-3 Starting lengths for temperature cables for 75 ft diameter bins Length from the center collar 216.1 in. (54.89 m) Length from 11.6 ft diameter location 148.5 in. (37.72 m) Length from 26.3 ft diameter location 56.6 in. (14.
78 ft Diameter Bin Figure 1-7 A-frame installation sequence and temperature cable locations for 78 ft diameter bin A 5 ft radius location (center collar) B 14 ft radius location C 28.6 ft radius location Table 1-4 Starting lengths for temperature cables for 78 ft diameter bins Length from the center collar 226.7 in. (57.58 m) Length from 14 ft diameter location 166.8 in. (42.37 m) Length from 28.6 ft diameter location 62.6 in. (15.
0 ft Diameter Bin Figure 1-8 A-frame installation sequence and temperature cable locations for 90 ft diameter bin A 5 ft radius location (center collar) B 14.8 ft radius location C 35.5 ft radius location Table 1-5 Starting lengths for temperature cables for 90 ft diameter bins Length from the center collar 268.9 in. (68.30 m) Length from 14.8 ft diameter location 202.1 in. (51.33 m) Length from 35.5 ft diameter location 55.4 in. (14.
5 ft Diameter Bin Figure 1-9 A-frame installation sequence and temperature cable locations for 105 ft diameter bin A 5 ft radius location (center collar) C 28.3 ft radius location B 10.3 ft radius location D 42.4 ft radius location Table 1-6 Starting lengths for temperature cables for 105 ft diameter bins Length from the center collar None Length from 10.3 ft diameter location 288.3 in. (73.22 m) Length from 28.3 ft diameter location 160.1 in. (40.67 m) Length from 42.
135 ft Diameter Bin Figure 1-10 A-frame installation sequence and temperature cable locations for 135 ft diameter bin A 12.3 ft radius location B 32.2 ft radius location C 55.4 ft radius location Table 1-7 Starting lengths for temperature cables for 135 ft diameter bins Length from the center collar None Length from 12.3 ft diameter location 318.8 in. (80.98 m) Length from 32.2 ft diameter location 239.4 in. (60.81 m) Length from 55.4 ft diameter location 67.9 in. (17.
NOTES 12 Pneg-1924
GSI Group, LLC Limited Warranty GSI Group, LLC Limited Warranty The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier.
This equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. GSI Group 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.gsiag.