Accessories PNEG-1885
4. Installation Instructions
22 PNEG-1885 Special 105' 2 Ring Door for Use with Enhanced Stiffeners in 3
rd
and 4
th
Ring
Sidewall and Stiffener Door Attachment (Continued)
Attach sidewall to outside of jamb plates. Use 7/16" x 2-1/2" (S-9444) bin bolt and recessed nuts
(S-8479) to attach sidewall to jamb plates. Place corrugated sealing strip (CWT-0053) between outer
and inner edges of the sidewall to jamb plate connection. Caulk around the sealing strip and around the
sidewall to header connection as well. (See Figure 4I.)
Figure 4I