Accessories PNEG-1846
3. 105' Diameter Eave Walk Around Package
12 PNEG-1846 “X” Series Complete 105' Walk Around Manual
1. Attach 105' exhaust walk around support (LDR-4426) to each roof rib. Platform supports should be
installed in the 1
st
and 2
nd
holes from the bottom of the roof rib using 5/16" x 1-1/4" bolts (S-277).
2. Leave bolts loose until all platforms are installed to ensure proper fit. Install counterclockwise to cover
tabbed portion of platform. (See Figure 3B.)
Figure 3B
3. Attach seam bracket and post brackets to sidewall and attach handrail post to support brackets.
NOTE: Handrail post do not attach directly to platform. (See Figure 3C.)
Figure 3C