60'-105' Bin Manager Temperature Cable Support Bracket Instructions Instruction Manual PNEG-1840 Date: 01-06-12 PNEG-1840
PNEG-1840 60'-105' Bin Manager Temperature Cable Support Bracket Instructions
Table of Contents Contents Chapter 1 Introduction ..........................................................................................................................................4 Chapter 2 Safety .....................................................................................................................................................5 Safety Guidelines ..................................................................................................................................
1. Introduction READ THIS MANUAL carefully to learn how to properly use and install equipment. Failure to do so could result in personal injury or equipment damage. INSPECT the shipment immediately upon arrival. The customer is responsible for ensuring that all quantities are correct. The customer should report and note any damage or shortage on the bill of lading to justify their claim to the transport company.
2. Safety Safety Guidelines This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections.
2. Safety General Safety Statement Our foremost concern is your safety and the safety of others associated with grain handling equipment. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel. As owner and/or operator, you are responsible to know what requirements, hazards, and precautions exist and inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel.
2. Safety Safety Instructions Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel. As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions exist, and to inform all personnel associated with the equipment or in the area.
2. Safety Prepare for Emergencies Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service, hospital, and fire department near your telephone. Keep Emergency Equipment Quickly Accessible Wear Protective Clothing Wear close-fitting clothing and safety equipment appropriate to the job. Eye Protection Remove all jewelry. Gloves Tie long hair up and back. Wear safety glasses at all times to protect eyes from debris.
3. Decals Roof Damage Warning and Disclaimer The manufacturer does not warrant any roof damage caused by excessive vacuum or internal pressure from fans or other air moving systems. Adequate ventilation and/or “makeup air” devices should be provided for all powered air handling systems. The manufacturer does not recommend the use of downward flow systems (suction). Severe roof damage can result from any blockage of air passages.
3. Decals ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal. GSI Decals 1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421 Rotating flighting will kill or dismember. Flowing material will trap and suffocate. Crusted material will collapse and suffocate.
3. Decals ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal. GSI Decals 1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421 WARNING DON’T DO UNLOADING INSTRUCTIONS: 1. Use CENTER FLOOR OUTLET ONLY until NO grain remains above this outlet. 2.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 20 Thousand Lbs.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 72' Temperature Cable Support Assembly Installation instructions: Attach left and right bracket assemblies to roof beams as shown in detail 4 on Page 14. Adjust bracket position along the roof beam to the desired radius. Tighten all 1/2" bolts to a minimum torque of 120 ft. lbs. Left bracket assembly (See detail 4 on Page 14.) Right bracket assembly (See detail 4 on Page 14.
4.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 72' Temperature Cable Support Assembly (Continued) NOTE: Internal mount only. Bin Diameter Temperature Cable Manufacturer Total Number of Cables Center Cable (Y/N) Cable 1 Radius (ft.) Cable 2 Radius (ft.) Cable 3 Radius (ft.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 20 Thousand Lbs.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 75' Temperature Cable Support Assembly Installation instructions: Attach left and right bracket assemblies to roof beams as shown in detail 10 on Page 18. Adjust bracket position along the roof beam to the desired radius. Attach support channel to the left and right bracket assemblies with 3/8" x 1-1/2" flange head bolts, washers and nuts. Attach hanging bracket to the support channel with 3/8" x 1-1/2" flange head bolts, washers and nuts.
4.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 75' Temperature Cable Support Assembly (Continued) Bin Diameter Temperature Cable Manufacturer Total Number of Cables Center Cable (Y/N) Cable 1 Radius (ft.) Cable 2 Radius (ft.) Cable 3 Radius (ft.) Temperature Cable Support Package 75' Diameter Bin Manager 13 N 4 at 10' 9 at 26' N/A CRP-6169 Temperature Cable Package Part # BMGR-7510-IC All specifications should be verified with the temperature cable manufacturer.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 20 Thousand Lbs.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 78' Temperature Cable Support Assembly Installation instructions: Attach left and right bracket assemblies to roof beams as shown in detail 16 on Page 22. Adjust bracket position along the roof beam to the desired radius. Attach support channel to the left and right bracket assemblies with 3/8" x 1-1/2" flange head bolts, washers and nuts. Attach hanging bracket to the support channel with 3/8" x 1-1/2" flange head bolts, washers and nuts.
4.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 78' Temperature Cable Support Assembly (Continued) Bin Diameter Temperature Cable Manufacturer Total Number of Cables Center Cable (Y/N) Cable 1 Radius (ft.) Cable 2 Radius (ft.) Cable 3 Radius (ft.) Temperature Cable Support Package 78' Diameter Bin Manager 14 N 4 at 10' 10 at 26-1/2' N/A CRP-6169 Temperature Cable Package Part # BMGR-7810-IC All specifications should be verified with the temperature cable manufacturer.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 20 Thousand Lbs.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 90' Temperature Cable Support Assembly Installation instructions: Attach left and right bracket assemblies to roof beams as shown in detail 22 on Page 26. Adjust bracket position along the roof beam to the desired radius. Attach support channel to the left and right bracket assemblies with 3/8" x 1-1/2" flange head bolts, washers and nuts. Attach hanging bracket to the support channel with 3/8" x 1-1/2" flange head bolts, washers and nuts.
4.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions 90' Temperature Cable Support Assembly (Continued) Bin Diameter Temperature Cable Manufacturer Total Number of Cables Center Cable (Y/N) Cable 1 Radius (ft.) Cable 2 Radius (ft.) Cable 3 Radius (ft.) Temperature Cable Support Package 90' Diameter Bin Manager 18 Y 6 at 18' 12 at 32-1/2' N/A CRP-6170 Temperature Cable Package Part # BMGR-9010-IC All specifications should be verified with the temperature cable manufacturer.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 20 Thousand Lbs.
4. 60'-105' Bin Manager Temperature Cable Bracket Instructions Special 25 Thousand Lbs.
NOTES 30 PNEG-1840 60'-105' Bin Manager Temperature Cable Support Bracket Instructions
5. Warranty GSI Group, LLC Limited Warranty The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier.
This equipment shall be installed in accordance with the current installation codes and applicable regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. GSI Group 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.gsiag.