0K and 20K Peak Capacity 50 PSF Ground Snow 90' Roof Assembly Assembly Manual PNEG-1790 Date: 08-08-12 PNEG-1790
PNEG-1790 10K and 20K Peak Capacity 50 PSF Ground Snow 90' Roof Assembly
Table of Contents Contents Chapter 1 Safety ..................................................................................................................................................... 4 Safety Guidelines .................................................................................................................................. 4 General Safety Statement .....................................................................................................................
1. Safety Safety Guidelines This manual contains information that is important for you, the owner/operator, to know and understand. This information relates to protecting personal safety and preventing equipment problems. It is the responsibility of the owner/operator to inform anyone operating or working in the area of this equipment of these safety guidelines. To help you recognize this information, we use the symbols that are defined below. Please read the manual and pay attention to these sections.
1. Safety General Safety Statement Our foremost concern is your safety and the safety of others associated with grain handling equipment. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel. As owner and/or operator, you are responsible to know what requirements, hazards, and precautions exist and inform all personnel associated with the equipment or in the area. Safety precautions may be required from the personnel.
1. Safety Safety Instructions Our foremost concern is your safety and the safety of others associated with this equipment. We want to keep you as a customer. This manual is to help you understand safe operating procedures and some problems that may be encountered by the operator and other personnel. As owner and/or operator, it is your responsibility to know what requirements, hazards, and precautions exist, and to inform all personnel associated with the equipment or in the area.
1. Safety Prepare for Emergencies Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service, hospital, and fire department near your telephone. Keep Emergency Equipment Quickly Accessible Wear Protective Clothing Wear close-fitting clothing and safety equipment appropriate to the job. Eye Protection Remove all jewelry. Tie long hair up and back. Gloves Wear safety glasses at all times to protect eyes from debris.
2. Decals Roof Damage Warning and Disclaimer The manufacturer does not warrant any roof damage caused by excessive vacuum or internal pressure from fans or other air moving systems. Adequate ventilation and/or “makeup air” devices should be provided for all powered air handling systems. The manufacturer does not recommend the use of downward flow systems (suction). Severe roof damage can result from any blockage of air passages.
2. Decals ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal. GSI Decals 1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421 Rotating flighting will kill or dismember. Flowing material will trap and suffocate. Crusted material will collapse and suffocate.
2. Decals ATTENTION: The decal shown below should be present on the outside of the door cover of the 2 ring, 24" porthole door cover and the roof manway cover. If a decal has been damaged or is missing in any of these locations, contact the manufacturer for a free replacement decal. GSI Decals 1004 E. Illinois St. Assumption, IL. 62510 Phone: 1-217-226-4421 WARNING DON’T DO UNLOADING INSTRUCTIONS: 1. Use CENTER FLOOR OUTLET ONLY until NO grain remains above this outlet. 2.
3. 90' Diameter Roof Instructions “Z” Collar and beam detail. (See detail 11 on Page 17.) Beam and stiffener detail. (See details 1 and 2 on Page 13.) “X” “X” Bracing Bracing and and purlin purlin detail. detail. (See (See details detail 10 on on Pages Page 17.) 15 and 16.) “X” Bracing bay detail. (See detail 10 on Page 17.
3.
Refer to Page 12 for inside and outside stiffened bin. 3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
3.
4. Roof Exhauster Placement Figure 4A below and Figure 4B on Page 27 shown is the recommended roof exhauster placement on the 90'-10K and 20K-50 PSF ground snow roof. Two (2) Z-shape reinforcement pieces (CRP-6447) are sent with the 90' roof for each exhauster. The reinforcement piece should be placed a minimum of 12" above the intermediate “Z” collar (CRP-4821) as shown in Figure 4B on Page 27 for side view detail.
NOTE: See roof exhauster manual (PNEG-524) for detailed assembly instructions, shown here are 135' roof exhauster placement recommendations. NOTE: Roof panels not shown for clarity. See top view on Page 26 for CRP-6447 attachment to beam. 4.
NOTES 28 PNEG-1790 10K and 20K Peak Capacity 50 PSF Ground Snow 90' Roof Assembly
5. Warranty GSI Group, LLC Limited Warranty The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14 months from arrival at port of discharge, whichever is earlier.
This equipment shall be installed in accordance with the current installation codes and applicable regulations, which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installations are made. GSI Group 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 www.gsiag.