2. Recommended Method for Full Floor Installation
PNEG-1567 54' Cor-Lok and Cut-Lok Flooring 11
Installation Instructions
1. When a splice is needed, plank length A as described in the floor manual should be installed
alongside plank length B.
2. The under-splice should then be installed under the split of plank A and B. The splice should extend
3" under each plank. The splice should be screwed in place as shown in Figure 2D on Page 10.
3. This process will be repeated for all plank locations requiring a splice.