User's Manual
FR566DG-INS-LAB-RevC13: Deluxe Clinical Care Recliner Assembly and Operating Instructions  10
SIDE PANEL OPERATION
For easy cleaning and access to the side and underside of the recliner, Lumex Clinical Care 
Recliners feature easy-to-remove side panels.
FR566G and FR566GH
To Remove Side Panel: depress 
the two push buttons located 
on the lower sides of frame. Pull 
side panel gently away and down 
from frame. There are tabs on the 
frame underneath the armrest 
that hold the side panel in place.
To Install Side Panel: insert 
side panel into recliner frame by 
locating the tabs underneath the 
armrest. Make sure side panel is 
properly aligned and that the top 
edge is behind the locking tabs. 
Press side panel into frame sides. 
Make sure that both push buttons 
are protruding into side panel to 
ensure side panel is locked into place.
FR566DG and FR566DGH
To Remove Side Panel: grasp upholstered 
side panel from both sides. Pull sharply out 
from recliner until locking clips release side 
panel from frame.
To Install Side Panel: insert side panel into 
recliner frame by lining up the side panel 
clips with the tubes on frame. Push side 
panel rmly into frame until side panel clips 
lock into place.
push button
panel tabs
side panel
FR566G and FR566GH Removable Side Panel
side panel
FR566DG and FR566DGH Removable Side Panel