User's Manual
Modu-Flo
®
System
8-2
42000
R
INSTALLATION INSTRUCTIONS
1. DISCONNECT INPUT AND LOAD POWER SUPPLIES
AT THEIR SOURCE.
2. REMOVE (2) SCREWS AND LIFT OUT CIRCUIT BOARD
3. INSTALL 1/2“ CONDUIT CONNECTOR IN .840
DIAMETER HOLE.
4. CONNECT INPUT POWER LEDS TO INPUT
TERMINALS. 110/220 VAC 50/60 HZ.
5. CONNECT LOAD LEADS TO LOAD TERMINALS.
110/220 VAC 50/60 HZ. 3 AMP MAX.
6. CONNECT REMOTE MANUAL RUN IF DESIRED
(CONTACT ONLY)
7. INSTALL TIMER BOARD WITH (2) =6 X 1/2“ SCREWS
SUPPLIED MAX. TIGHTENING TORQUE 5 IN. LBS.
8. SET TIMER ON AND OFF TIMERS
9. CLOSE AND FASTEN COVER WITH 2 =10 X 3/4“
SCREWS SUPPLIED MAX. TIGHTENING TORQUE 7 IN
LBS AND APPLY POWER.
1/2 AMP
3 AMP
INPUT
LOAD
0.2
1
2
5
7
10
13
ON TIME
MINUTES
CAUTION
DISCONNECT A LOCK
OUT POWER PRIOR
TO SERVICING TO AVOID
POSSIBLE ELECTRICAL
SHOCK.
INPUT
115/230V
50/60 HZ
LOAD
3 AMP
MAX.
MAN
RUN
LOAD ENERGIZED
LUBRIQUIP
TOTAL CYCLE TIME
HOURS
MINUTES
TOTAL CYCLE TIME
MINUTES’ HOURS
5
2
4
8
16
24
32
30
24
16
8
4
2
5
ASSY NO
572-142-590
MANUAL RUN BUTTON
Figure 8-2. AC Timer Wiring Schematic
12 to 32 VDC
POWER SOURCE
ORANGE
(MEMORY)
RED (+)
BLUE (+)
SWITCH
SOLENOIDBLACK
TIMER
GROUND
( – )
( + )
YELLOW ( – )
Figure 8-1. DC Timer Wiring Schematic